Routine Maintenance; Maintenance Schedule - CleanCraft HDR H-78-18 Manual De Instrucciones, Uso Y Mantenimiento

Hidrolavadoras de agua caliente
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 44
• Wind up the high pressure hose (35) with due care, making sure it is not bent. For products without a
hose reel, hang it up on its support (10).
• Wind up the power cord (6) and hang it up on its support (10).
• Store the high pressure cleaner in a clean, dry place. Make sure the power cord and the high pressure
hose are not damaged.
Follow the instructions for
MAINTENANCE
SCHEDULE
Every time the cleaner
is used
Once a Week
Once a Month
28
STORAGE

ROUTINE MAINTENANCE

and those provided in the table below.
"STOPPING WORK"
• Check the power cord, the high pressure hose, the connectors, the cleaner
gun and the lance pipe.
Should any of these look damaged, do not use the cleaner for any reason
and contact a
qUALIFIED TECHNICIAN
• Check the water inlet filter (18) and clean it if necessary.
Use a coin (Fig. 1 and 2) to turn the screw (37) anticlockwise and lower the
door (33).
Unscrew the cup (62) and take the filter cartridge (61) out.
Running water or compressed air is generally all that is needed to clean
the filter cartridge. In difficult cases, use a lime scale remover or replace the
filter cartridge. For tough cases, use a lime scale remover or replace it by
contacting a
qUALIFIED TECHNICIAN
Replace the filter and put the cover back, following the above steps in reverse
order.
• Clean the nozzle.
To clean the nozzle, it is generally sufficient to insert the pin (31) supplied
into the nozzle's hole. If no appreciable results are obtained, contact a
qUALIFIED TECHNICIAN
using a 14 mm/0.55" spanner (not supplied).
• Clean the detergent suction filter (58).
It is normally enough to put the filter under running water or blow it with
compressed air to clean it. In the more difficult cases use a water softener
or replace it, contacting a
• Check the pump oil level.
Use the dipstick (51) (Fig. 2). If you need to top up the oil, contact a
TECHNICIAN.
• Cleaning the fuel fill up filter (59).
Unscrew the fuel tank cap (7) to reach the fill up filter. Take the filter out and
remove any impurities. In the more difficult cases replace it, contacting a
SPECIALIZED TECHNICIAN
ACTION
.
to buy the spare part.
to buy the spare part . The nozzle can be replaced
SPECIALIZED TECHNICIAN
to buy a new one.
to buy a new one.
qUALIFIED

Publicidad

Tabla de contenido
loading

Tabla de contenido