7.3 PROGRAMMING.
Configuration of 4 different programs: "Reduced", "Cyclic",
"Progr_1" (personalised) e "Progr_2" (personalised).
• REDUCED.
For programming a single switch-on and a single switch-off event
during the day.
• CYCLIC.
For programming a switch-on and a switch-off period that are
repeated cyclically.
For example, entering "On hh mm 1.15" and "Off hh mm 1.30",
the contact will continually repeat the sequence "contact ON for 1
hour and 15 minutes" - "contact OFF for 1 hour and 30 minutes".
• PROGR_1 e PROGR_2.
Personalised programs. For setting up 2 different switch-on and
switch-off programs for each individual day of the week, for a
maximum of 35 switch events a day.
Confirm "ok" (button D) = scrolling menu with a choice of
"Modify", "Copy" and "Rename".
- Modify.
Allows the user to set up or edit the switch-on and switch-off
program, if desired by copying a program from one of the other
days.
14 - ENGLISH
- Copy.
For copying a program that has already been configured by the
user into one of the programs that is still to be configured.
- Rename.
For assigning a name to or renaming the chosen program.
8. RESET PROCEDURE.
• Simultaneously press the four buttons (button A, button B, button
C, button D)
• Confirm with "Yes" (button D).
Restores the original first power-up conditions; all parameters are
reset to their default values.
9. CHARACTERISTICS.
• Supply voltage: 120-230 V~ 50-60 Hz
• Average absorption: 1 VA
• Front controls: "Esc", "" "", "Set"/"ok"
• Clock backup battery duration: about 10 days, with type CR2032
battery
• Output: 8 A 230 V~ change-over relay output
• controllable loads:
- purely resistive loads
: 8 A