Lewmar Pro Fish Serie Manual De Instalación, Operación Y Servicio página 15

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
KIT NO
DESCRIPTION
66000096
Pro-Series Stripper Arm Kit
66000098
Pro-Series Clutch Nut & Cone Kit
66000099
Clutch Lever
66000101
504 Gypsy RC 8mm (5/16")
66000102
516 Gypsy RC 5/16" G4
66000768
Pb Gypsy (14-16mm Leaded Line)
66000769
Dual Gypsy RC 6mm - 7mm -1/4"
66000634
Bearing Kit
66000616
Pro-Fish Conversion Kit
66000617
Pro-Fish Stopper Kit
66000620
Pro-Fish Drive Cap Assembly Kit
66000758
Pro-Series Washer Kit
66000759
Pro-Series Gasket Kit
66000760
Pro-Series Coumpound Gear kit
66000761
Pro-Series Gears & Shaft Kit
66000762
Pro-Series Gear Train Cover Kit
66000763
Pro-Series 12V Motor Kit
66000764
Pro-Series Seals & Screw Kit
66000766
Pro-Guard / Control Arm Kit
8- Troubleshooting
1. Anchor rode pays out independently while windlass is not in use.
• This problem is a result of not securing the anchor rode combined with the gypsy drive cap being
slack. Tighten the gypsy drive cap using the winch handle and always secure the anchor rode
independently of the windlass when not in use.
2. Failure to operate or sluggish operation.
• The majority of these problems are electrical in nature. It is essential that the proper voltage be
maintained. The proper voltage on a 12 Volt system is 13.5 Volts, constant low voltage will damage
motor.
Ensure electrical cable size is large enough to handle the current draw and keep voltage drop within
acceptable limits.
• Check control switches, connections, battery condition, isolator switch, fuse and motor for
operation failure.
3. Failure to operate.
• Is there a voltage at the input terminals to the contactor and switches. Check the circuit breaker/
isolator switch and any fuses.
• Operate the switch. Is there voltage at the positive switch terminal on the solenoid. If not, the switch
(or its wiring), is difective.
• Keep the switch activated. Is there voltage at the main output terminal on the contactor. If not check
the contactor coil ground circuit. If okay, replace the contactor.
• Check the voltage at the motor. If voltage of at least 12.5 volts is present and the motor does not
operate, the motor is defective.
ITEMS INCLUDED (QTY)
37(1), 53(1), 54(2)
35(1), 36(1), 43(2)
Clutch lever (not shown)
58A(1)
58B(1)
58C(1)
58(1)
2(1), 4(1), 5(1), 6(2), 56(1), 57(1)
8(1), 9(1), 10(1), 11(1), 12(1), 13(1),14(1), 15(1), 16(1), 17(1), 20(1), 54(2)
9(3), 54(2)
8(1), 10(1), 11(1), 12(1), 13(1),14(1), 15(1), 16(1), 17(1), 20(1)
21(1), 22(1), 23(2), 27(1)
24(1), 25(6)
5(1)
2(1), 3(1), 6(2), 23(2), 28(1), 33(1), 34(1), 45(1), 46(1), 51(1)
4(1), 18(1), 24(1), 25(6). 42(1), 55(6), 57(1)
26(1), 33(1), 38(1), 45(1), 50(2), 52(3)
2(1), 3(1), 7(1), 24(1), 25(6), 26(1), 39(2), 42(1), 43(2), 45(1), 52(3), 53(2), 54(3), 55(6)
29(1), 30(1), 31(1), 41(1), 44(1), 48(1), 54(3)
Lewmar Pro-Series/Fish windlass ref B10414 iss.1
|
15

Publicidad

Tabla de contenido
loading

Tabla de contenido