Other Publications; Hydraulic Schematic - Greenlee LHFS-210003 Especificaciones Y Piezas

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Other Publications

Tool Owners/Users
Operation Manual: Publication 99930331
SAE Standard J1273 (Hose and Hose Assemblies): Publication 99930323
Authorized Greenlee Utility Service Centers
Service Manual: Publication 99914590
Purpose
This manual is intended to familiarize all personnel with the specifications
and parts for the following Greenlee Utility product:
LHFS-210003 Serial Code FFD
Keep this manual available to all personnel.
Replacement manuals are available upon request at no charge at
www.greenlee.com.
Specifications
Hydraulic Pruner
Type of Hydraulic System ........................................................................Open-Center
Hydraulic Ports
Pressure ............................................................................................... 3/8" NPTF
Tank ...................................................................................................... 3/8" NPTF
Cutting Capacity ..................................................................................44 mm (1.75")
Noise Levels
L
(Sound Power Level) .............................................................................. 70 dB
WA
Vibration .......................................................................................................2.5 m/s
Mass/Weight ....................................................................................... 3.5 kg (7.7 lbs)
Length ................................................................................................1520 mm (60")
Width ...................................................................................................152 mm (6.0")
All specifications are nominal and may change as design improvements occur. Greenlee Textron
Inc. shall not be liable for damages resulting from misapplication or misuse of its products.
KEEP THIS MANUAL
Greenlee / A Textron Company
Hydraulic Power Source
Do not exceed the following hydraulic power source maximums:
• Hydraulic flow: 22.7 l/min (6 gpm)
• Pressure relief: 138 bar (2000 psi)
• Back pressure: 13.8 bar (200 psi)
Failure to observe this warning could result in severe injury or death.
Type of Hydraulic System ........................................................................Open-Center
Flow
Minimum ..................................................................................15.1 l/min (4 gpm)
Recommended ..........................................................................18.9 l/min (5 gpm)
Maximum ..................................................................................22.7 l/min (6 gpm)
Filtration ..................................................................................... 10 Micron (nominal)
Pressure Relief Setting ...................................................................138 bar (2000 psi)
Back Pressure (Maximum)* .............................................................13.8 bar (200 psi)
* 13.8 bar (200 psi) is the maximum agreed standard back pressure for the HTMA
(Hydraulic Tool Manufacturers Association). Greenlee Utility tools will operate
satisfactorily at this standard.
1.
Maximum hydraulic fluid temperature must not exceed 60 °C (140 °F).
A sufficient oil cooling capacity is needed to limit the hydraulic fluid
temperature.
2.
Hydraulic flow must not exceed 22.7 l/min (6 gpm). Install a flow meter in the
return line to measure to rate of hydraulic flow before using the tool.
3.
Pressure relief valve setting must not exceed 138 bar (2000 psi) at your tool's
maximum flow. Locate the pressure relief valve in the supply circuit to limit
2
excessive hydraulic pressure to the tool.

Hydraulic Schematic

RESERVOIR
(2000 psi)
PUMP
POWER SOURCE
Recommended Hydraulic Fluids
Use any non-detergent, petroleum-based hydraulic fluid which meets the following
specifications or HTMA specifications.
S.U.S. @:
38 °C (100 °F)...................................................................................... 140 to 225
99 °C (210 °F)....................................................................................40 minimum
Flash Point ......................................................................... 170 °C (340 °F) minimum
Pour Point ........................................................................... -34 °C (-30 °F) minimum
4
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
LHFS-210003
FILTER
(10 MICRON)
RELIEF
COOLER
VALVE
138 bar
T
CONTROL
VALVE
FLOW METER
P
TOOL

Publicidad

Tabla de contenido
loading

Tabla de contenido