Keep away from the pump outlet/discharge hose
during operation. Liquid and debris will be thrown
by the pump.
Failure to observe this warning can result in severe
injury or death.
Do not inspect, adjust, or clean tool when it is
connected to a power source. Accidental startup
can result in serious injury.
Skin injection hazard:
Oil under pressure easily punctures
skin causing serious injury, gan-
grene or death. If you are injured by
escaping oil, seek medical attention
immediately.
• Do not use fingers or hands to
check for leaks.
• Do not hold hose or couplers while
operating the power source.
• Depressurize the hydraulic system
before servicing.
Wear eye protection when operating
or servicing this tool.
Failure to wear eye protection can
result in serious eye injury from
flying debris or hydraulic oil.
Greenlee / A Textron Company

Operation

1. Connect the discharge hose to the discharge port.
2. Start the power source.
Note: Allow the power source to run for a few
minutes to warm the hydraulic fluid.
Do not use the hydraulic hoses to lower or lift the
pump. This will weaken or damage the hoses or
fittings, and could cause a hydraulic fluid leak.
Failure to observe this precaution can result in
property damage.
3. Attach a rope or other device to the handle of the
pump. Lower the pump into the material to be
pumped.
4. Actuate the control valve of the power source to start
the flow of hydraulic fluid.
5. When finished pumping, actuate the control valve to
stop the flow of hydraulic fluid.

Maintenance

Use this maintenance schedule to maximize the tool's
service life.
Note: Keep all decals clean and legible. Replace decals
when necessary. See Specifications and Parts manual
for decal part numbers.
Daily
1. Wipe all tool surfaces clean.
2. Inspect the hydraulic hoses and fittings for signs of
leaks, cracks, wear or damage. Replace if necessary.
3. Install dust caps over the hydraulic ports when the
tool is disconnected.
Monthly
1. Perform a thorough inspection of the hydraulic hoses
and fittings as described in publication 999 3032.3,
SAE J1273 (Hose and Hose Assemblies).
2. Model H4635 and H4670 only: Remove and clean
the base legs and base plate. Remove any material
that may have accumulated near the inlet port.
7