Section Iii. Equipment Maintenance - Eclipse 58920100 Instrucciones Y Manual Del Propietario

Filtro de arena de gran rendimiento
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

K. CLEANING THE HIGH FLOW™ MANUAL AIR RELIEF VALVE.
1.
Turn the pump off and shut off any automatic controls to ensure
that the system is not inadvertently started during servicing.
2.
OPEN THE HIGH FLOW™ MANUAL AIR RELIEF VALVE
UNTIL IT SNAPS INTO THE FULL OPEN POSITION, THEN
WAIT UNTIL ALL PRESSURE IS RELIEVED.
3.
With the High Flow™ manual air relief valve attached to the filter
tank, pull out the locking tabs and remove the valve stem and
cover assembly with a counter-clockwise and lifting motion, see
Figure 2.
4.
Clean debris from the valve stem and body. Verify that the filter
tank's air passage is open by inserting a 5/16 in. drill bit through
the valve body. Verify that the O-rings are in good condition,
properly positioned, and lubricated with a silicone based lubricant.
5.
Reinstall the valve stem and cover assembly with a downward and
clockwise motion until it snaps into position.

SECTION III. EQUIPMENT MAINTENANCE.

A. AIR ENTERING YOUR FILTER IS DANGEROUS AND CAN CAUSE
THE LID OR VALVE TO BLOW OFF.
1.
Correct any conditions in your filtration system that allow air to
enter the system.
2.
Some common ways to identify air entering the system are:
a.
Low water level in pool or spa - skimmer is starving for water with pump running. Add water to pool or spa.
b.
Air bubbles or low water level in pump hair and lint pot are caused by: Low water level, clogged skimmer basket, split
suction cleaner hose, leak in pump hair and lint pot lid, or leak in pump suction line.
c.
Air bubbles coming out of water return lines into the pool or spa with pump running, see Steps 2.a. and 2.b. above.
d.
Air is discharged from the High Flow™ manual air relief valve on top of the filter when the valve is opened with the pump
running, see Steps 2.a. and 2.b. above.
B. THE PRESSURE GAUGE IS YOUR PRIMARY INDICATOR OF HOW THE FILTER SYSTEM IS OPERATING.
1.
It is an important part of your filter system.
2.
Maintain your pressure gauge in good working order.
3.
Check the operation of your pressure gauge in the following manner:
a.
The pressure gauge should go to zero (0) when the system is turned off and pressure is relieved.
b.
The pressure gauge should indicate pressure when the system is operating.
c.
The pressure gauge should be readable and not damaged in any way.
d.
Replace the pressure gauge if any of the above conditions exist.
P/N • Núm/Pte. • Réf. P/N 99226000
8
Figure 2.
Rev. H • Rev. H • Rév. H
12-9-99

Publicidad

Tabla de contenido
loading

Productos relacionados para Eclipse 58920100

Este manual también es adecuado para:

5892020058920300

Tabla de contenido