Maintenance; Troubleshooting; Repairs - ROTOR Sanamat RSI Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

CH-3661 Uetendorf

10. MAINTENANCE

-
The motor bearings are permanently lubricated and therefore require no maintenance.
-
The grating disc wears out and has to be replaced annually.

11. TROUBLESHOOTING

PROBLEM
The appliance doesn't run
Grinding noise
Too much pressure needed to push
down the plunger, vegetables and
fruits not correctly cut (too big)
The appliance vibrates
Very noisy (testing without the
centrifugal basket!)

12. REPAIRS

Obtain the address of your nearest Rotor Lips authorized service center from the store
where you purchased your appliance.
When returning the unit for repairs use a shockproof packing and well upholster the
machine!
Repairs on electrical appliances should only be carried out by
professional technicians. Serious dangers can result to the user from
improper repairs.
Attention!
When the appliance mains cable becomes damaged, it shall only
be replaced by an original cable.
Instruction Manual
Rotor Sanamat RSI
CAUSE / SOLUTION
- Make sure the mains cable is plugged into
a wall socket
- The safety clasp is properly closed
- Press the appliance switch off,
and press again
- Check the fuse in the corresponding building
electrical circuit
- The machine is not correctly mounted.
Please refer to chapter „Operating
intructions"
- grating disc is worn out. Replace grating disc
in centrifugal basket
- Pulpe chute is blocked
- Motor or electronics are defective. Stop the
machine immediately and get it repaired
© Rotor Lips AG
23

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

1216.0011216.0021216.0061216.008

Tabla de contenido