2.21 Motor Controller Communication Codes
Code
EN
F-0884
F-05C1
F-05C2
F-05C3
F-05C4
F-05C5
F-05C6
28
Message
Sequence code
Battery Discharge
SOC<3% - GO! S1.2/GO! S1.2+;
Indicator - Warning
SOC<10% - GO! S2.4/GO! S2.4+
Battery Discharge Cut-out
- Warning
Low Battery Voltage -
Warning
High Battery Voltage -
Warning
Hight Capacitor Voltage -
Warning
Low Battery Voltage -
Warning
Limit
Please shut off scooter and restart the ignition
with the kill switch in the "Off " position.
The operator should charge the battery. When
the battery is full charge the operator can
resume riding.
The operator should charge the battery. When
SOC<1%
the battery is full charge the operator can
resume riding.
The operator should charge the battery. When
80V - GO! S1.2/GO! S1.2+;
the battery is full charge the operator can
56V - GO! S2.4/GO! S2.4+
resume riding.
The operator should leave scooter in idle state
114V - GO! S1.2/GO! S1.2+;
(ignition ON) for 2-3 minutes, battery balancing
112V - GO! S2.4/GO! S2.4+
in process.
The operator should leave scooter in idle state
114V - GO! S1.2/GO! S1.2+;
(ignition ON) for 2-3 minutes, battery balancing
112V - GO! S2.4/GO! S2.4+
in process.
The operator should charge the battery. When
39.1V
the battery is fully charge the operator can
resume riding.
Action