6. CONVERT WAIST HIGH BROILER
BURNER ORIFICE FLAME FOR LP GAS
(Self-clean models only).
1. Open oven door.
2. Locate broiler burner spud and turn down approximately
2-1/2 turns so that spud is snug against LP metering pin. Do
not overtighten.
3. To determine if burner flame is proper, push the BROIL
button, then turn the SET knob to the LO setting, and
observe broiler flame. It should be steady and sharp with
approximately 1" blue cones and no yellow or orange flame
tips.
AIR SHUTTER
4. If adjustment to the air shutter is necessary, locate oven
burner air shutter, loosen shutter set screw and adjust shut-
ter to obtain optimum flame. This will normally be com-
pletely open for LP gas. Tighten shutter set screw.
MODEL AND SERIAL NUMBER
LOCATION
MODEL AND SERIAL PLATE LOCATION
The model and serial plate is located in the left hand side,
underneath the surface cooktop.
When ordering parts for or making inquiries about your
range, always be sure to include the model and serial
numbers from the serial plate on your range.
Your serial plate also tells you the ratings of the burners and
type of fuel and pressure the range was adjusted for when it
left the factory.
PIN
NAT.
L.P.
SPUD
7
SERIAL PLATE
IMPORTANT SAFETY WARNING
SEE PAGE 8 FOR
ANTI-TIP BRACKET
INSTALLATION INSTRUCTIONS
NOTE:
Refer to Owner's Guide for complete instructions for
ordering parts or making inquiries about this range.
NOTE:
Refer to Owner's Guide for operating instructions and
cleaning instructions.
BEFORE YOU CALL FOR SERVICE
Check to make sure the house fuses or circuit breaker for
your range are not blown or open.
CARE, CLEANING AND
MAINTENANCE
If removing the range is necessary for cleaning or
maintenance, shut off gas supply. Disconnect the gas and
electric supply. If the gas or electrical supply is inaccessible,
lift the unit slightly at the front and pull out away from the
wall. Pull only as far as necessary to disconnect the gas and
electric supply lines. After disconnecting the gas and
electric supply, finish removing the unit for servicing and
cleaning. Reinstall in reverse order making sure to level the
range and check gas connection for leaks.