Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

INSTR, USER MANUAL, EN / ES MEX / FC, VT1512-IP - P/N: 10029038 Rev-A - INK: BLACK - MATERIAL: 16 LB. MEAD BOND - SIZE: 8.500" x 11.000"; SCALING 1-1 - FOLDING: ALBUM FOLD - BINDING: SADDLE-STICH
VT1512-IP
VT1512-IP
A BlueBOLT ® Enabled Vertical Rack Power Conditioner with12 Outlets
CUSTOM INSTALL POWER MANAGEMENT
Congratulations on your purchase of the Panamax VT1512-IP BlueBOLT enabled vertical rack power
conditioner and power sequencer. The VT1512-IP is a full featured power conditioner providing protection
and filtration for maximum longevity and performance of connected equipment. BlueBOLT enabled, the
VT1512-IP allows remote reboot of 12 individually controlled outlets, as well as the ability to monitor energy
use, set alerts, program scheduled commands, network pings with conditional reboot and much more.
FEATURES
Protect-or-Disconnect surge protection
Standard EMI/RFI Filtration
Over/Under voltage load disconnect
Power Sequencing
IP Monitor & Control - BlueBOLT™ enabled for IP control and monitoring
12 individually controlled outlets, 3 spaced for wall-warts & 6 turned 90°
Ground lug to attach Panamax signal-line protection modules
Sleek design ideal for vertical mounting to an equipment rack with included brackets
10 foot power cord with removable plug to customize length
15A Capacity with circuit breaker
3 year limited product warranty
$5,000,000 Connected Equipment Protection Policy when used with Panamax
signal-line protection modules.
Important: You will need the VT1512-IP's unique MAC Address and Challenge
Key (provided on the 2 labels attached to the cover of this guide, as well as
on a label on the bottom of the product) to register the unit for control and
monitoring at www.mybluebolt.com. One is permanently adhered and the other
is removable for your convenience.
You can find the VT1512-IP manual on the product page at
under the Resource tab.
www.panamax.com
IMPORTANT SAFETY INSTRUCTIONS
1.
Read these instructions.
2.
Keep these instructions.
3.
Heed all warnings.
4.
Follow all instructions.
5.
WARNING: Do not use this apparatus near water. To reduce the
risk of fire or electric shock, do not expose this apparatus to rain
or moisture.
6.
CAUTION - Could Contain Always On Receptacles (depending on
BlueBOLT programming). To reduce risk of shock - Disconnect
VT1512-IP from power source before servicing any equipment
connected to VT1512-IP.
7.
Clean only with dry cloth.
8.
Do not install near any heat sources such as radiators, heat
registers, stoves, or other apparatuses that produce heat.
9.
Do not defeat the safety purpose of the polarized or grounding
type plug. A polarized plug has two blades, with one wider than
the other. A grounding type plug has two blades and a third
grounding prong. The wide blade or the third prong is provided
for your safety. If the provided plug does not fit into your outlet,
consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched,
particularly at plugs, convenience receptacles, and the point
where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Refer all servicing to qualified service personnel. Servicing is
required when the apparatus has been damaged in any way,
such as power-supply cord or plug is damaged, liquid has been
spilled or objects have fallen into the apparatus, the apparatus
has been exposed to rain or moisture, does not operate normally,
or has been dropped.
13. Where the power cord is used as the main disconnect device,
the disconnect device shall remain readily accessible.
14. This device must be connected to a main socket outlet with a
protective earthing (ground) connection.
PRINTER'S INSTRUCTIONS:
Custom Install Power Management
MODEL: VT1512-IP
BEFORE YOU BEGIN UNPACKING
Inspect the unit upon receipt. In addition to this guide, the
box should contain the following:
(2) Mounting Brackets
(4) Pan Head Machine
Screws with Grommets
www.panamax.com
Instruction Manual
Table of Contents
VT1512-IP Instruction Manual-English . . . . . . . . . . . . . 2
Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
BlueBOLT®. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Product Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Advanced Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
VT1512-IP Advanced Operation . . . . . . . . . . . . . . . . . . . . . 4
Status. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Message Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Common Attributes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Query Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Action Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Password Protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
VT1512-IP Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Technologies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Limited Three Year Warranty. . . . . . . . . . . . . . . . . . . . . . . . 16
FCC Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Montaje. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
BlueBolt®. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Características del producto. . . . . . . . . . . . . . . . . . . . . . . . . 19
Operaciones avanzadas . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Operación avanzada del VT1512-IP . . . . . . . . . . . . . . . . . . 20
Estado . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Controles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Configuración . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Tipos de mensaje . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Atributos Comunes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Comandos de consulta. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Comandos de acción . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Protección de contraseña. . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Solución de problemas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Especificaciones del VT1512-IP . . . . . . . . . . . . . . . . . . . . . . 30
Tecnologías. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Información de garantía . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Garantía limitada de tres años . . . . . . . . . . . . . . . . . . . . . . 32
Aviso FCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Fixation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
BlueBOLT®. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Caractéristiques Du Produit . . . . . . . . . . . . . . . . . . . . . . . . . 35
Opérations avancées . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Opérations avancées du VT1512-IP . . . . . . . . . . . . . . . . . . 36
État. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Commandes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Types de message. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Attributs communs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Commandes de requête. . . . . . . . . . . . . . . . . . . . . . . . . . . 39
(2) Insulation Gaskets
Commandes d'action. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Protection par mot de passe. . . . . . . . . . . . . . . . . . . . . . . . . 44
Dépannage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Caractéristiques techniques du VT1512-IP. . . . . . . . . . . . . . 46
Technologies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Information Sur La Garantie . . . . . . . . . . . . . . . . . . . . . . . . . 48
Garantie limitée de trois ans. . . . . . . . . . . . . . . . . . . . . . . . 48
(8) Flat Head Machine
Avis De La FCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Screws
1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Panamax VT1512-IP

  • Página 1: Tabla De Contenido

    PRINTER’S INSTRUCTIONS: INSTR, USER MANUAL, EN / ES MEX / FC, VT1512-IP - P/N: 10029038 Rev-A - INK: BLACK - MATERIAL: 16 LB. MEAD BOND - SIZE: 8.500” x 11.000”; SCALING 1-1 - FOLDING: ALBUM FOLD - BINDING: SADDLE-STICH VT1512-IP...
  • Página 2: Vt1512-Ip Instruction Manual-English

    Rocker Power Switch: Circuit Breaker: LED Indicators: Insulator sheet Use the eight flat head machine screws to at attach both brackets to the VT1512-IP. Outlets 1 - 3: Spaced to accommodate large transformers (wall warts). 37 in. Plan for and allow...
  • Página 3: Advanced Operations

    "query". Whether the task is an "action" or "query", the message is classified as a command and is firmware version, bootcode version and brand and model number. To find the VT1512-IP IP address, you can claim the device in BlueBOLT one time and look under Device ADMIN for the IP contained within the <command>...
  • Página 4: Common Attributes

    Instruction Manual - English VT1512-IP Common Attributes Example 2: Query Command Message with xid – Some message elements will include a timestamp attribute “time”. The timestamp is in standard UNIX time, up to 10 decimal digit characters, and represents the number of seconds that have passed since January 1st 1970 GMT.
  • Página 5: Action Commands

    Instruction Manual - English VT1512-IP Sample Response – Action Commands <status time=”1234567890”> Switch Outlet Action <voltage>119.14</voltage> The Switch Outlet action is used to turn ON or turn OFF an outlet. <voltpeak time=”0”>0.00</voltpeak> Sample Action – <amperage>0.00</amperage> <wattage>0.00</wattage> <outlet id=”2”>0</outlet> <pwrva>0.15</pwrva> Details – <pwrfact>0.00</pwrfact>...
  • Página 6 Sample Event – Events <schedmgr> By default, the VT1512-IP will not send any event messages. To receive event messages a Subscribe Action must be sent after each device reset, reboot or power up. <fire> <day>127</day> See Subscribe Action section for details.
  • Página 7: Password Protection

    PASSWORD PROTECTION TROUBLESHOOTING Once you have claimed your VT1512-IP, you can set up password protection. To do so you need to enter the Local IP address of the VT1512-IP card into your browser. You can locate the Local IP Address by GENERAL USE: clicking on Device Admin within the BlueBOLT user interface.
  • Página 8: Vt1512-Ip Specifications

    Product weights and dimensions The VT1512-IP can be monitored and controlled via an internal web page for LAN applications, or you can use the BlueBOLT cloud to monitor, control and program your device from anywhere in the world via your computer or mobile device.
  • Página 9: Warranty Information

    Puede encontrar el manual VT1512-IP en la página del producto en www.nortekcontrol.com • www.panamax.com • www.mybluebolt.com aislamiento arandelas cabeza plana www.panamax.com en la pestaña Recursos. ©2019 Nortek Security and Control, LLC. All rights reserved. Panamax and BlueBOLT are trademarks of Nortek Security and Control, LLC. www.panamax.com www.panamax.com...
  • Página 10: Vt1512-Ip Manual De Instrucciones-Español

    CA contra el estado de la función de desconexión de carga por sobre / bajo voltaje del VT1512-IP. Si el voltaje de línea es inferior a 85 Vac o superior a 140 sobretensiones para la garantía del equipo Vac, las salidas se cerrarán y el indicador de Protección OK parpadeará...
  • Página 11: Operaciones Avanzadas

    "consulta". Si la tarea es una "acción" o "consulta", el mensaje se clasifica como un comando y Ethernet (MAC ID), la versión del firmware, la versión del código de arranque y la marca y el número de modelo. Para encontrar la dirección IP de VT1512-IP, puede verificar el dispositivo en Usuario está...
  • Página 12: Mensajes De Evento

    VT1512-IP Manual de instrucciones - Español Atributos Comunes Ejemplo 2: Mensaje de consulta de comando con "xid" - Algunos elementos del mensaje incluirán un atributo de marca de tiempo "tiempo". La marca de tiempo está en la hora estándar de UNIX, hasta 10 caracteres decimales, y representa el número de segundos que han pasado desde el 1 de enero de 1970 GMT.
  • Página 13: Comandos De Acción

    VT1512-IP Manual de instrucciones - Español Respuesta de muestra - Comandos de acción <status time=”1234567890”> Acción cambiar de salida <voltage>119.14</voltage> La acción cambiar de salida se usa para ENCENDER o APAGAR una salida. <voltpeak time=”0”>0.00</voltpeak> Acción de muestra - <amperage>0.00</amperage>...
  • Página 14 UDP donde se deben enviar mensajes de eventos. Puede ser una dirección IP diferente a la que el sistema de control que envió la solicitud. Evento de mensaje Eventos <schedmgr> Por defecto, el VT1512-IP no enviará ningún mensaje de evento. Para recibir mensajes de eventos, se debe enviar una Acción de suscripción después de cada reinicio o encendido de cada <fire> dispositivo. <day>127</day>...
  • Página 15: Protección De Contraseña

    PROTECCIÓN DE CONTRASEÑA SOLUCIÓN DE PROBLEMAS Una vez que haya reclamado su VT1512-IP, puede configurar la protección con contraseña. Para hacerlo, debe ingresar la dirección IP local de la tarjeta VT1512-IP en su navegador. Puede localizar BlueBOLT Interfaz de configuración USO GENERAL: la dirección IP local haciendo clic en Administrador de dispositivos en la interfaz de usuario de...
  • Página 16: Especificaciones Del Vt1512-Ip

    Largo 37 " IP Monitor y Controll El VT1512-IP se puede monitorear y controlar a través de una página web interna para aplicaciones LAN, o puede usar la nube BlueBOLT para monitorear, controlar y programar su dispositivo Anchura 1.75 ”...
  • Página 17: Información De Garantía

    • www.mybluebolt.com tête plate avec œillets du produit à l'adresse www.panamax.com sous l'onglet Resources (Ressources). © 2019 Nortek Security and Control, LLC. Todos los derechos reservados. Panamax y BlueBOLT son marcas comerciales de Nortek Security and Control, LLC. www.panamax.com www.panamax.com...
  • Página 18: Caractéristiques Du Produit

    Disjoncteur : Voyants à DEL : Feuille isolante Utilisez les huit vis à métaux à tête plate pour fixer les deux supports au VT1512-IP. Prises 1 - 3 : espacées pour accueillir de grands transformateurs (adaptateurs muraux). 94 cm (37 po).
  • Página 19: Opérations Avancées

    / Protection par mot de passe activée Le VT1512-IP dispose une page Web intégrée pour les utilisateurs souhaitant l'utiliser sur un réseau LAN. La page Web intégrée affiche le numéro de série des unités, leur adresse Ethernet « action » ou une « query », le message est classé comme une commande et est contenu dans l'élément <command>.
  • Página 20 VT1512-IP Manuel d'instructions - français canadien Attributs communs Exemple 2: Requête de commande avec « xid » – Certains éléments de message incluront un attribut horodateur « time ». L'horodatage est à l'heure UNIX standard, avec un maximum de 10 caractères décimaux, et représente le nombre de secondes écoulées depuis le 1er janvier 1970 UTC.
  • Página 21 VT1512-IP Manuel d'instructions - français canadien Exemple de réponse – Commandes d'action <status time=”1234567890”> Action Basculer la prise <voltage>119.14</voltage> L'action Basculer la prise permet d'allumer ou d'éteindre une prise. <voltpeak time=”0”>0.00</voltpeak> Exemple d'action – <amperage>0.00</amperage> <wattage>0.00</wattage> <outlet id=”2”>0</outlet> <pwrva>0.15</pwrva> Détails – <pwrfact>0.00</pwrfact> <pwrcond>0</pwrcond>...
  • Página 22 <min>775</min> <command><outlet id=”7”>0</outlet></command> Les messages d'événements seront répétés par le VT1512-IP jusqu'à ce qu'un message d'accusé de réception lui soit renvoyé, ou après un délai d'attente d'environ 20 minutes. </fire> Le message d'accusé de réception doit contenir les mêmes valeurs d'attribut « evtid » et « subs » que le message d'événement.
  • Página 23: Protection Par Mot De Passe

    Une fois que vous avez enregistré votre VT1512-IP, vous pouvez configurer la protection par mot BlueBOLT Interface de configuration de passe. Pour ce faire, vous devez entrer l'adresse IP locale de la carte du VT1512-IP dans votre UTILISATION GÉNÉRALE : navigateur.
  • Página 24 Niveau de serrage initial 200 V en crête, 141 RMS Lorsque la tension entrante revient à un niveau sécuritaire, le VT1512-IP s'allume automatiquement et revient à l'état dans lequel il était avant l'événement de surtension ou de sous-tension. Dissipation d'énergie 200 joules Séquencement de l'alimentation électrique...
  • Página 25: Vt1512-Ip Manuel D'instructions-Français Canadien

    5919 Sea Otter Pl., Suite 100, Carlsbad, CA 92010 www.nortekcontrol.com • www.panamax.com • www.mybluebolt.com © 2019 Nortek Security and Control, LLC. Tous les droits sont réservés. Panamax et BlueBOLT sont des marques commerciales de Nortek Security and Control, LLC. www.panamax.com 10029038 Rev-A...

Tabla de contenido