Descargar Imprimir esta página

Antec PHANTOM 350 Manual Del Usuario página 4

Ocultar thumbs Ver también para PHANTOM 350:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

1.4 INRUSH CURRENT
115V/60A(max), 230V/80A(max.) at 25°C cold start
1.5 POWER EFFICIENCY
Minimum efficiency at full load per Intel testing standard, 115V/230Vac 60/50Hz
Version
Efficency
US
86% without PFC
EC
82% with PFC
2.0 OUTPUT:
VOLTAGE
+5V
+12V
MAX. LOAD
30A
MIN. LOAD
0.3A
REGULATION
±5%
RIPPLE& NOISE (mV)
50
NOTE:
1. The continuous max DC output power shall not exceed 350W. +5V,
+12V1, +12V2, and +3.3V output power shall not exceed 334W.
2. Ripple & noise test condition: AC 115V/230V 60/50Hz at full load
2.1 HOLD-UP TIME: 20ms (minimum)
Test Condition: 1. Full load. AC input 115V/230V, 57Hz/47Hz
2.2 LOAD TRANSIENT RESPONSE (STEP LOAD)
Step load changes of up to 20% of full load, while other loads remains constant
within the rating. The load waveform shall be a square wave with the slope of
the rise and fall at 1A/µsec and the frequency shall be from 10Hz to 1kHz. The
DC output voltage will stay within regulation during the step load changes.
2.3 OVERSHOOT
Overshoot at turn-on shall be less than 10% of the nominal output voltage.
3.0 PROTECTION:
If the power supply is latched into shutdown stage (when OCP, OVP, OPP or
short protection is working), the power supply shall return to normal operation
only after the fault has been removed and should reset PS-ON for a minimum of
1 second. Then it will turn on again.
3.1 INPUT UNDER VOLTAGE
The power supply shall contain protection circuitry such that application of an
input voltage below the minimum specified in Section 1.1 shall not cause any
damage to the power supply.
+12V
+3.3V
-12V
1
2
16A
18A
28A
0.5A
0.3A
0.3A
0.3A
0A
±5%
±5%
±3%
±5%
120
120
50
120
3
3.2 OVER CURRENT PROTECTION
SENSE LEVEL
12V
12V
+5V
+3.3V
3.3 OVER VOLTAGE PROTECTION
SENSE LEVEL
+5Vsb
12V
& 12V
1
2.0A
+5V
0A
+3.3V
±5%
50
3.4 SHORT CIRCUIT PROTECTION
All output to ground.
3.5 UNDER VOLTAGE PROTECTION
SENSE LEVEL
12V
& 12V
1
+5V
+3.3V
3.6 OVER TEMPERATURE
The power supply includes an over-temperature protection sensor, which can
trip and shutdown the power supply at 110°C. Such an overheated condition is
typically the result of internal current overloading or a cooling fan failure.
3.7 OVER LOAD PROTECTION
Overload currents to output rail will cause the output trip before they reach or
exceed 110% ~ 140% for protection, the overload currents should be ramped
at a minimum rate of 10A/s starting from full load.
4.0 TIME SEQUENCE
T1
Power-On Time (500msec. max.)
T2
Rise-time (20msec. max.)
T3
Power Good Delay Time (100msec. < t3 <500msec)
T4
Power Fail Delay Time (1msec. min.)
T5
Hold-Up time (20msec. min)
OVER CURRENT
17.6A min
20.8A max
1
19.5A min
23.4A max
2
33.0A min
45.0A max
30.8A min
42.0A max
OVER VOLTAGE
13.3V min
14.3V max
2
5.7V min
6.2V max
3.7A min
4.1A max
UNDER VOLTAGE
9.5V min
10.5V max
2
4.1V min
4.47V max
2.55 Vmin
2.83V max
4