Possible Faults
FAULT
INSUFFICIENT FLOW
- Insufficient suction pipe diameter.
- Suction valve partially open.
- Air intake on the suction.
- Very viscous liquids.
- Wrong turning direction.
- Blocked filter.
- Incorrect installation of the suction pipe
with counter gradients that cause the
formation of air pockets.
- Working pressure higher than the
maximum, which causes the safety valve
to open.
INSUFFICIENT OR UNSTABLE PRESSURE
- Suction valve partially closed.
- Air intake on the suction.
- Wrong turning direction.
- Counter gradients on the suction that
cause the formation of air pockets.
LEAKS THROUGH THE MECHANICAL SEAL OR LIPSEALS
- Impurities in the pumped liquid.
- Damaged friction faces due to working
dry, damaged lip seals.
BLOCKING OF THE TURNING PARTS
- Suction of foreign bodies.
ABNORMAL WORKING OF THE MOTOR
- Incorrect electric supply.
- Incorrect motor connection.
- Partial blocking in some part of the pump. Clean the inside and check for damage
THE PUMP ABSORBS EXCESSIVE POWER
- Very high density or viscosity of the liquid.
- The pump works outside the maximum
pressure curve.
LEAK THROUGH PUMP & MOTOR OPENING
- Damaged mechanical seal or lip seal.
EXCESSIVE WORKING TEMPERATURE
- Incorrect ventilation of the equipment.
- Very high pumping temperature.
SYSTEMATIC FAULTS OF THE MECHANICAL SEAL OR LIPSEALS
- Abrasive particles in the fluid.
Manual de instrucciones/Manual/Manuel d'instructions "
"R" SERIES
SOLUTION
Change a diameter equal to or greater than the
pump
Clean or change
Check all suction connections
Heat liquid
Change rotation
Clean
Check the installation, delete counter slope
Regular pressure
Check valve-change
Review all the unions included installation
Change rotation
Check the installation, delete counter slope
Insert filter, change the mechanical seal or seal
Switch closure or seal
Clean the inside and check for damage
Check voltage
Check connections
Heat liquid
Regular pressure
Switch closure or retention
Ensure ventilation or relocate
Check temperature of liquid
Avoid placing particulate filter