Cleaning, Care & Maintenance; Troubleshooting - Buffalo CP829 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
Should the parameter need adjusting:
1. Press
twice. The display will show "PAS".
2. Press
or
to input correct password (The
default value is 15).
3. Press
to confirm. The system enters the
parameter code selecting mode.
4. Press
to select the desired parameter code.
The display will show the lower setpoint limit,
the higher setpoint limit, the temperature
hysteresis, time delay of starting the machine,
and the Cabinet temperature probe adjustment
consecutively.
5. Press
to confirm. The system enters the
parameter value setting mode. Press
until the required value is displayed.
6. Press
again to confirm the selected
parameter value. The system now exits the
parameter value setting mode and returns to
the previous parameter code selecting mode.
Note: If the password is correct,
you can adjust parameters.
Otherwise, you can only view
parameters.

Troubleshooting

Fault
The unit is not
The unit is not switched on
working
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
Poor heating effect
Poor ventilation
Door is opened frequently or not
shut properly
Food is too cold or too much food in
the appliance
Temperature improperly set
Loud noises
The appliance has not been installed
in a level or stable position
Loose screw/nut
Odour from the unit Unit is not cleaned for long time
Odour foods are not properly packed Seal and pack odour foods properly
CP829_ML_A5_v3_20190826.indb 5
Cleaning, Care &
Maintenance
Clean the interior of the appliance as often as
possible.
Do not use abrasive cleaning agents. These
can leave harmful residues.
Clean the door seal with warm soapy water.
or
Always wipe dry after cleaning.
Cleaning the water trays
Empty the tray on the interior back wall. Wipe
dry with a kitchen towel if needed.
Pull the other tray out of the brackets on the
underside. Empty and Wipe dry.
Probable Cause
Switch off and disconnect
the appliance from the power
supply. Allow to cool down
before cleaning.
Solution
Check the unit is plugged in correctly and
switched on
Call BUFFALO agent or qualified Technician
Replace the plug fuse
Check power supply
Call BUFFALO agent or qualified technician
Increase ventilation
Check door is shut and seals are not
damaged
Remove excessive food
Re-set the temperature
Check installation position and change if
necessary
Check and tighten all nuts and screws
Clean the unit thoroughly
UK
5
2019/8/26 13:37

Publicidad

Tabla de contenido
loading