Layout of the control panel
The air conditioner is equipped with a remote control
system.
Its mode of operation is the same as the user
functions on the control panel.

Description of the control panel

1. Temperature
Press the ∆ button to raise the temperature and the
button to lower the temperature.
2. Sleep function
If the SLEEP button is pressed in cooling mode, the
temperature will be raised 1°C above the set
temperature after 1 hour.
3. Fan
The fan speed (air rate) can be regulated with the
HIGH and LOW buttons.
4. Timer
The timer can be set for a range of 1 to 12 hours. If
the timer is not set at all, the appliance will switch off
automatically after 24 hours.
5. Display window
The display shows: the room temperature
the time setting
the temperature setting
6. Swing
If you press the SWING button, the vertical air grilles
will swing from side to side for uniform distribution of
the air. The horizontal air grilles have to be adjusted
by hand.
12
30.10.2001 7:15 Uhr
7. Functions
Press this button to select the following settings:
Automatic, Cooling, Air Circulation.
8. ON/OFF button
Remote
Use only this button to switch the appliance on and
control
off.
receiver

Starting the air conditioner

POWER PLUG
STARTING
SETTING
A FUNCTION
SETTING THE
TIME AND
TEMPERATURE Press the temperature UP or
SWITCHING OFF Press the ON/OFF button for the
To protect the compressor it is triggered with a
delay of 3 minutes after the appliance is switched
on. The same applies when the appliance is
switched off.
The function settings are cancelled when the
appliance is switched off or when there is a
power failure. In this case you will need to reset
the functions as required.
The cooling system switches off when the room
temperature is lower than the value set on the
thermostat. Air circulation / ventilation continues
in accordance with the settings. If the room
temperature rises again, the cooling function will
be reactivated.
Seite 12
Insert the power plug in a socket-
outlet. The current room
temperature appears in the
display on the control panel.
Press the START button. The
appliance will then start
automatically. If the temperature
is below 23 °C, only the fan will
run.
Press the FUNCTION button to
select the required setting:
Automatic, Cooling or Ventilation
temperature DOWN button to set
the temperature of your choice.
Press the TIMER button to set
the operating time.
appliance to be switched off
immediately.