Maintenance and adjustment
Adjusting the suction valve:
In order to increase suction power, the valves located underneath your cleaner can be
adjusted by pulling out the rim of the valve.
Before lowering the rim of the valve, make sure there is enough clearance and the unit
movements won't be obstructed by any obstacles on the swimming pool floor or walls,
such as (drains, steps, etc.)
1) To pull out the rim rotate counterclockwise using a screwdriver (Fig. A)
2) To retract the rim rotate clockwise using a screwdriver (Fig. B)
Cleaning the pump propeller:
1) Take out the screws from the outlet top
2) Take out the outlet top and remove hair and other debris around propeller
A
Screws
outlet top
propeller
IMPORTANT TIPS:
Shut off and unplug the power supply every time you remove the cleaner from the
!
water.
Clean the filter bag after every cycle.
!
Periodically straighten out the floating cable.
!
Replace worn brushes to ensure maximum cleaning performance
!
Save your cleaner's packaging for off-season storage or for shipping the unit to your
dealer if service is required.
Leave your pool cleaner in the water for 15 to 20 minutes after every cleaning cycle.
!
Do not leave your cleaner in direct sunlight when not in use.
!
Never leave the power supply in direct sunlight and avoid leaving it in the rain.
!
B
Occasionally, you should rinse your cleaner in clean, fresh water. This will lengthen
!
the service life of the drive belts, drive tracks and scrubbing brushes.
Clean the propeller once a month
!
CLIMBING UNITS WITH FLOATING HANDLE ONLY
If your unit has floating handle, reverse the diagonal position after every cleaning
!
cycle to avoid tangling the cable.
Make sure that your pool cleaner positions itself properly on the wall. The machine
!
handle must rest parallel to the water line upon reaching the surface of the water.
IMPORTANT:
Please be sure to always keep your pool cleaner properly stored anywhere between
10 to 40 degrees Celsius (50 to 104 degrees Fahrenheit). This will keep the motors,
plastics and seals protected. Failure to comply will result in loss of warranty.
Robot can be used in water with temperatures ranging from 13°C to 35°C (55°F to
95°F). However, the recommended optimal temperature is between 22°C and 32°C
(72°F and 90°F)
IMPORTANT:
The transformer cord can only be replaced with the aid of special tools,
normally available only to authorized dealers, distributors and service centers.
6