8.1.3
Flushing canister internal cleaning
Time to time clean the inside of the flushing canister:
WARNING: Protect your eyes and hands from solid particles being projected.
8.2
Periodical operations
In order to guarantee unit's proper functioning, verify periodically, the most exposed to wear
and tear components. For this is suggested to check frequently:
Service hoses: must have no cuts, no abrasions or blowing-up
Automatic connectors: must have no wear and tear evident signs, hardening during service
and must be rightly connected to the service hoses.
8.3
Safety operations
In order to guarantee unit's proper functioning, it is necessary to verify periodically the safety
components. The verification period is suggested after 24 months from first activation date.
This operation can be made only and exclusively by TEXA and/or authorised TEXA's Service
Centre.
ACKF01_GB_00
a) Make sure that the canister is empty from any
refrigerant.
Remove the chromed cap of the tap located at the base
of the flushing canister and open the blue valve.
b) Flush through the canister inlet with a shop-air
gun, contaminations will be pushed out through the tap.
It is suggested to install a little container under the
canister, in order to recover the flushed contamination.
c) When finished, close the valve of the tap, and re-install
the cap.