Troubleshooting Table; Spare Parts; Technical Information - THERMOBILE BX Serie Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
6.1

Troubleshooting table

/i
Fault
The heater is not
functioning.
The fan does not turn
and there is no heat.
Positions 2 and 3:
The fan turns as nor-
mal but there is little
heat, 50%.
Record the maintenance details in table A in
the annex at the back of this manual.
7

SPARE PARTS

Contact the dealer for the use of spare parts.
8

TECHNICAL INFORMATION

For technical specifications, see table B
in the annex at the back of this manual.
For the electrical circuit diagram, refer to
diagram C in the annex at the back of this
manual.
BX3 / BX9 / BX15
BX3 / BX9 / BX15
Cause
1
The heater has no volt-
age.
2
Defect in the operating
panel.
3
Phase - exchange the
ZERO wires in a 5-pole
connector/female con-
nector.
4
The thermostat is set to
a too low temperature.
5
Fuse is faulty in your
system.
6
Fan motor is broken.
7
Cable of the extension
cable has been pinched.
(Wire interrupted.)
8
Fuse is faulty in your
system.
9
Cable of the extension
cable faulty.
10 Heater functions on 2
phases.
40.020.959 - rev. 04 - 2011
40.020.959 - rev. 05 - 2013
Solution
Check the electrical connec-
tion.
Repair or replace the operat-
ing panel.
Repair the connection.
Correct the settings.
Replace the fuse. (Make sure
it is tight.)
Replace the fan motor.
Repair the connection.
Replace the fuse. (Make sure
it is tight.)
Repair the connection.
Repair the connection.
English
Action
User
Dealer
User
User
User
Dealer
User
User
User
User
17