PROBLEM
Rubber broom stops while
brushing.
CAUSE
 The motor is
overloaded.
 The battery pack or the
power head is too hot.
 The battery pack is
disconnected from the
tool.
 The battery pack is
depleted.
 Still not start beyond
the above reasons.
RUBBER BROOM ATTACHMENT — RBA2100/RBA2100-FC
SOLUTION
 The motor will
recover when the
load is removed. For
continuous work,
decrease the load on
the rubber broom.
 Allow the battery pack
or the power head
to cool until the its
temperature drops
below 152°F (67°C).
 Re-install the battery
pack.
 Charge the battery pack
with an EGO charger
listed in this manual.
 Contact EGO Customer
Service.