Installation
IMPORTANT : Please follow the safety advice set out on pages 3 to 5.
- DO NOT wire/fit a plug to this appliance. The appliance
must be electrical connected to a fused fixed spur, which
is fitted with a 13Amp fuse.
- All fittings must be installed by a competent person in
accordance with the current IET Wiring Regulations
(BS7671). If in doubt, consult a qualified electrician.
- This product is suitable for use in living areas, and Bathroom
(dry) outside Zones and zone 2 only (see diagram below
and current IET Wiring Regulations for details). It is not
suitable for Bathroom Zones 0 and 1. If being fitted in a
bathroom a 30mA RCD must be used. This appliance
does not come fitted/supplied with a fused plug.
- Always refer to the Reference Drawing for Bathroom
Installation.
Note : the below drawing is for reference only.
(DRY) OUTSIDE ZONES
ZONE
2.25m
ZONE
IP24: THIS PRODUCT IS SUITABLE FOR BATHROOMS
(DRY) OUTSIDE ZONES AND ZONE 2
- Full details can be found in the current IET Wiring
Regulations (BS7671).
1
0.6m
ZONE
2
0
ZONE
2
0.6m
28
Ceiling
Window
recess