Condenser Cleaning - Nordcap KU 510 FISCH CNS Manual De Instrucciones

Equipo frigorífico
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
The defrosting is carried out automatically with electronic control, which can also be triggered manually. In any case, do not use sharp objects
(such as knives, screwdrivers, etc.) to remove a possible excess of ice. In models with automatic defrost water evaporation, water is drained to the
condensing unit. In other models, it is drained to a tray underneath the equipment which must be poured regularly. After defrost, keep the doors
and/or drawers closed to accelerate the temperature recovery.
5.3. Cleaning
To ensure proper hygiene and maintenance, perform regular cleaning as indicated:
Switch off the appliance and unplug it, or switch off the circuit breaker;
Clean the surfaces using a dampened cloth with a mild soap warm water solution; then rinse with a dampened cloth with clean water
and finally wipe with a soft, dry cloth;
Do not use aggressive cleaning products containing corrosive chemicals or chlorine (such as bleach), or abrasive materials (such as
pads) or pressurized water (such as hoses).

5.4. Condenser Cleaning

To ensure long life and correct operation of the refrigeration system, clean the condenser coil regularly as indicated:
Switch off the appliance and unplug it, or switch off the circuit breaker;
Unscrew and open the air vents grid; be careful with cable holder, do not stretch the cables;
Carefully vacuum (preferably) or brush the condenser coils;
Finally, screw back the air vents grid.
5.5. Extended Period of Inactivity
Where there is a foreseeable extended period of inactivity, remove all foodstuff from the appliance and clean it as described. In the end, switch
it off from the mains and leave the doors open to prevent bad odour.
5.6. Use of swivel castors brake
Brake
5.7. Troubleshooting
If you notice any malfunction, refer to the checklist below to identify the problem and its possible solutions. If the problem still persists, please
contact the after-sales service.
Equipment does not run and the display does not work
Equipment does not run but the display works
Equipment is not cold enough
Equipment is too cold
Equipment runs continuously
Equipment starts and stops frequently
MNS00065.01
MKT
Instruction Manual
Symptom
Release the brake
Make sure the plug is inserted into the socket
Check for a blown fuse or tripped circuit breaker
Test the power outlet for current
Inspect the electrical cord for damage
Remove any extension cord
Check the temperature setting
Assure that there is enough air flow inside the equipment
Clean the condenser coils
Check the temperature setting
Assure that there is enough air flow inside the equipment
Check for airflow restrictions in vents
Clean the condenser coils
Clean the door seals
Check for a clogged drain pipe
Check the temperature setting
Clean the condenser coils
Clean the door seals
Clean the condenser coils
N.º MNS00065.01
Check
6/24