Maintenance And Cleaning Instructions - Hoshizaki HNC-120AE-L Manual De Instrucciones

Vitrina para mostrador
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
ENGLISH
9. To prevent damage to the
glass parts, do not place or
hit any tableware, bottles
or edged tools directly on
the glass surfaces. Even
a tiny flaw may grow into a
crack (a few days) later.
0. To a v o i d e n t r a n c e o f
vermin during operation,
the two drain outlets, on
the right and left under the
food mounts must always
have the drain plugs fitted.
) Clean inside the showcase.
2) Plug in the showcase, and turn on the Power
Switch.
* When not in use, dry the showcase thoroughly
and store it in a dry place.
III. MAINTENANCE AND CLEANING
INSTRUCTIONS
IMPORTANT
. B e f o r e c a r r y i n g o u t a n y c l e a n i n g o r
m a i n t e n a n c e o p e r a t i o n s , u n p l u g t h e
showcase.
2. Do not disassemble the showcase further
than illustrated in Fig. .
3. D o n o t t o u c h o r w e t t h e m a c h i n e
compartment parts. This could result in
failure or breakdown.
1. INTERIOR/EXTERIOR
* Clean the interior and Food Mounts every day for
sanitary use.
* Use a soft cloth soaked in warm water to clean
off the exterior. Do not use a water jet to clean
the exterior.
* Use only a neutral cleaner. Other chemical
agents might cause damage to the interior and
exterior surfaces.
Note: To prevent damage to the part surfaces and
the plating on the Evaporator, do not use a
scourer on the interior/exterior surfaces.
2. DRAIN PIPE CLEANING
) Either mix  liter of water with 3.7 ml of 5.25%
sodium hypochlorite solution in a suitable
container, or the recommended Hoshizaki
sanitizer as directed.
2) Disconnect the Hose from the Joint.
3) Turn up the end of the two Joints .
4) Slowly pour the sanitizing solution into the drain
water circuit from the Joints.
5) Wait for 5 minutes, and turn down the end of the
Joints to drain the solution.
6) Leave the drain water circuit to dry out.
3. AIR FILTER
A plastic mesh air filter removes dirt or dust from
the air, and keeps the Condenser from getting
clogged. As the filter gets clogged, the showcase'
s performance will be reduced. Check the filter
at least twice a month. When clogged, use warm
water and a neutral cleaner to wash the filter.
) Hold the tabs located at the
bottom of the Louver, and lift
them up to release the Louver
from the body.
2) Pull the Louver toward you.
3) Pull out the Louver downward.
4) Hold the frame of the Air Filter, and pull it out
toward you.
5) Clean the Air Filter.
6) Refit the Air Filter and Louver in the reverse
order of the removal procedure.
4. CONDENSER
IMPORTANT
To prevent possible injury, do not touch the
Condenser Fins with hands. Use a brush or
vacuum cleaner to clean the Condenser.
Check the Condenser once a year, and clean
if required by using a brush or vacuum cleaner.
4
Fig. 7

Publicidad

Tabla de contenido
loading

Tabla de contenido