INITIAL OPERATING CONDITION
The manufacturer supplies the radio control unit
ready to be used with codes preset in the Factory

OPERATION MODE

Standard configuration:
Standard configuration requires all "cooker hoods
– radio control - system" to be provided with the
same transmission code. In the event two cooker
hoods – radio control system are installed in the
same room or nearby, each system may affect
the operation of the another. Therefore, the code
of one radio control system must be changed.
Generating a new transmission code:
The radio control system is provided with preset
codes. Should new codes be required, proceed
as follows: Press simultaneously buttons:
for two seconds. When Leds light on, press but-
tons:
(within 5 seconds). Leds flashing 3 times indicate
the procedure is completed.
WARNING! This operation deletes permanen-
tly the preset codes.
Learning the new transmission code:
Once the transmission code is changed in the ra-
dio control unit, the electronic central unit of the
cooker hood must be made to set the new code
in the fol- lowing way:
Press the main power-off button (fig. 15) of the
hood and then restore power to the electronic
control unit. Within the next 15 seconds, press
the Liight Button
unit with the code.
Reset of the Factory configuration:
To restore the Factory configuration, follow the
procedure described below: press simultaneou-
sly buttons:
to synchronise the central
for 2 seconds. When Leds light on, press buttons:
(within 5 seconds). Leds flashing 6 times indicate
the procedure is completed.
WARNING! This operation deletes permanen-
tly the preset codes.
Emergency button:
In the event that the radio control does not work,
use the emergency button to switch the appliance
off. After any necessary repairs have been perfor-
med, reset the emergency button.
WARNING
The battery should be replaced every year to
guarantee the optimal range of the transmitter.
To replace the exhausted battery, take the pla-
stic lid off, remove the battery and replace it
with a new one, observing the correct battery
polarities.
Used batteries should be discarded in special
collection bins.
The below product:
RC001 Radiio Controll
complies with the specifications set out in the
R&TTE Directive 99/5/EC.
WARNING
Any adjustments or modifications which have
not been expressly approved by the holder of
the legal conformity certificate may invalidate
the user's rights relating to the operation of
the device.
The products are endowed with an electronic de-
vice which allows the automatic switching off after
4 hours working from the last operation.