Anti-freeze function
When the device is off and the temperature
surrounding the temperature sensor drops
to below 6° C, the device will switch on au-
tomatically. This is to prevent the heating
agent inside the radiator from freezing. The
activation of Anti-freeze mode is indicated
by the blinking of the middle diode.
Dryer function
The Dryer turns the device on for 2 hours,
e.g. in order to dry a towel. After this peri-
od of time the device automatically switch-
es to the mode to which it was set before
the dryer mode.
Dryer function can be activated during
heater operation by pressing button. You
can now freely adjust desired temperature
level (buttons
will revert to the previous setting (before
dryer function activation). To use 2 hrs tim-
er heating element must be switched off.
Switch it on by pressing
2 hrs heater will switch off automatically.
Press
button at any time to interrupt the
dryer mode.
16
User manual MOA www.termaheat.pl
and ). After 2 hrs heater
button. After
Calibrating the temperature span
The standard temperature span of the
heating element is 30-60° C. It is possible
to increase or decrease that span by setting
a maximum temperature of between 45° C
and 65° C, (minimum temperature of 30° C
stays unchanged). This allows the user to
achieve a maximum temperature which is
higher than the standard or to effectively
heat a space with the device during lower
surrounding temperatures.
Example: for the temperature regulation
span of up to 45° C (30-45° C) modification
by one step (one diode), means increase/
decrease of temperature by 3.75° C, while
for the temperature regulation span of up
to 65° C (30-65° C) modification by one step
means increase/decrease by 8.75° C.
In order to modify the temperature span,
unplug the device and plug it back in, while
pressing
button. A single diode will start
blinking on the display panel. Use
buttons to set one of the 5 possible maxi-
mum temperatures. The first diode stands
and