Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

INTRODUCTION
The Battery Kit, NiMH type (HP Battery), or Sealed Lead Acid version (SL Battery), is a specific accessory for GE BTP e GE BP
Inflators. The units are provided with a RED Power Connector for the Inflator, and a BLACK circular jack to recharge the battery as
well. The Kit is protected by a 30A fuse.
Main Features of HP Battery
6.
Nominal Voltage
7.
Rated Capacity
8.
Max. Discharge Current
9.
Charging time
10. Life Cycles
WARNING!
Before using for the first time, or after a long period of inactivity, ensure the battery is fully charged.
Using a charger other than that supplied in the kit may damage the battery.
If left uncharged, even for a short time, batteries risk swift and permanent damage. After use, recharge the battery as soon as
possible!
The guarantee does not cover premature damage made to the battery caused by a failure to recharge.
Charging the battery:
Insert the charger's charging plug to the circular connector of the battery.
A.
B.
Choose the appropriate supply cable (USA or Europe); plug it into the seat on the battery charger and in the mains
plug (from 100 to 240 AC).
C.
The red LED light comes on during charging; the battery is charged when the green LED light comes on.
D.
As soon es the battery is charged, disconnect the battery charger from the mains and from the battery in order to avoid
the battery running down.
CONNECTING THE BATTERY TO THE INFLATOR
3.
Open the carton and take the battery out.
4.
Put the battery in the inflator pocket and connect the RED power connector to the inflator.
WARNING!
Do not leave the unit running unattended. Over-inflation of items could result in serious injury. Excessive air
pressure may cause a hazardous risk of bursting or personal injury. Check the manufacturer's maximum pressure
rating for items being inflated.

TROUBLESHOOTING

PROBLEM
POSSIBLE CAUSE
Battery LOW
ON push button not ON
Unit will not Start
The safety fuse is blown
Unit is damaged
Wrong port connected
Unit will not inflate
Wrong setting on the pressure knob
ACCESSORIES
Recommended accessories for use with your inflator are available from your local dealer or authorized service center.
WARNING!
The use of any accessory not recommended for use with this inflator could be hazardous.
Main Features of SL Battery
12V DC
Nominal Voltage
10 Ah
Rated Capacity
25 A
Max. Discharge Current
8 hours ca.
Charging time
800 ca.
Life Cycles
Instruction Manual – Manuale d'istruzioni – Bedienungsanleitung
Manuel d'instructions - Manual de instrucciones
12V DC
9 Ah
25 A
8 hours ca.
500 ca.
POSSIBLE SOLUTION
Recharge the battery by the 110-240Vac battery charger
Push ON PB
Replace the fuse with one of the same size (30 A).
Contact SCOPREGA Service Center
Connect the air hose to the proper port.
Adjust settings.