READ AND SAVE THESE INSTRUCTIONS
WARNING!
READ THE INSTRUCTIONS CAREFULLY TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY
1. Use this unit only in the manner intended by the manufacturer. If you have questions, please contact the
manufacturer.
2. Before servicing or cleaning the unit, switch off the power at the service panel and lock it to prevent accidental
switching. If the switch is not equipped with a safety locking device, attach a prominent warning tag to the service panel.
3. Installation work and electrical wiring must be performed by qualified personnel in accordance with all applicable
codes and standards including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhaust of gases through the flue (chimney) of fuel burning
equipment to prevent backdrafting. Follow the heating equipment manufacturer's guidelines and safety standards such
as those published by the National Fire Protection Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. While cutting or drilling into wall or ceiling make sure not to damage electrical wiring and other hidden utilities.
6. Fans with exhaust ducts must always be vented to the outdoors.
7. This unit may have sharp edges. Use caution to avoid being cut when installing and cleaning.
8. This unit must be grounded.
CAUTION!
1. For general ventilating use only. For use in non-fire-rated installations only.
Do not use for propelling hazardous or explosive materials and vapors.
2. For interior use only. Mount with the lowest moving parts at least 8 feet (2.5 meters) above the floor or grade level.
3. To avoid motor damage and noisy and/or unbalanced impeller, keep power unit clean from drywall spray,
construction duct, etc
4. Before installing the unit check for any visible damage of impeller and housing.
The housing internals must be free of parts which can damage the impeller blades.
5. Please read the specification label on the product for further information and requirements.
6. Not for installation by children or any person unable to follow these safety guidelines.
7. Connect via a switch built into the fixed wiring. The gap between the breaker contacts on all poles must be
not less than 1/8".
8. To ensure optimal air passage do not close or block the unit inlets and outlets.
Do not sit or put objects on the unit.
0
9. Store the fan in manufacturer's packaging in a ventilated room at temperatures between 41 and 104 F and relative
humidity not more than 80%.