3.4. SMP-94RZ1 CONFIGURATION.
Each SMP-94RZ1 must be configured with a number of zone
(from 1 to 240) by means of the corresponding dipswitches
(figure 6b, number 1).
Follow table 3 to configure each SMP-94RZ1.
When a paging is sent to a zone by a desk, the SMP-94RZ1
module configured with that number switches the signal
received from the Program line (PROGRAM +/-) with the
signal received from the Priority line (PRIORITY +/-).
The number of zone of a module can be changed only altering
the position of the dipswitches, and pressing Reset (figure 6a,
number 1).
TABLA 3 / TABLE 3 / TABLE 3 / TAULA 3.
3.4. CONFIGURACIÓ SMP-94RZ1.
Mitjançant els dipswitchs corresponents (figura 6b, número 1),
cal configurar cada SMP-94RZ1 amb un número de zona (de
1 a 240).
Per a configurar cada SMP-94RZ1 cal seguir la Taula 3.
Quan, mitjançant un pupitre, es dóna un avís a una zona, el
mòdul SMP-94RZ1 configurat amb aquell número de zona
commuta el senyal que li arriba per la línia de Programa
(PROGRAM +/-) amb el senyal que li arriba per la línia de
Prioritat (PRIORITY +/-).
Si es vol canviar el número de zona d'un mòdul només cal
variar la posició dels dipswitchs i polsar el reset (figura 6a,
número 1).