SAFETY CRITERIA
1
Attention: before starting any kind of procedure is absolutely necessary to read all
this manual.
2
Test/Control that the performances of the actuator correspond to your installation
needs.
3
Check that:
• The gate hinges are in good conditions and perfectly fastened.
• The gate has mechanical stops in the opening and the closing.
INSTALLATION ADVICE
Connections:
•
See the "Operal diagram" and refer to the control central scheme.
•
The electric cable in the exit from the actuator must not be tight, but has to do an
ample curve towards the botton to avoid the reflux in the inside of the actuator.
(Fig. O)
•
The adjustment must be done without power supply.
•
Foresee an omnipolar breaking device near to the apparatus (the contact must
measure at least 3 mm) Always protect the power supply using a 6A automatic
switch, or a 16A single-phase switch fuses.
•
The power supply lines to the motors, to the control unit and the connection lines
to the outfits must be separated to avoid troubles which can cause problems in the
installation working.
•
Any outfits (of control or safety) eventually connected to the control unit must be
tension free.
Spare parts:
•
Use esclusively original spare parts.
•
Throw away the batteries as waste products. (Law n. 475/88).
Installation:
•
In order to use correctly the product and to exclude the possibility of injury or
damage, refer to the "Generals" page enclosed, which is an integrated part of this
manual.
•
The use of this equipment must be in observance of the safety standards in force
in the country where it is installed, as well as the standards governing proper way
of installation.
Warranty:
•
The warranty supplied by the manufacturer becomes vain in the event of
interference, carelessness, improper use, lightening damage, power surges or
use by unqualified personnel.
•
The warranty will also become vain in case of failure to observe the instructions
given in the manuals supplied with the product, in case of application of any part in
a different way from what established by current legislation, or the use of spare
parts not suitable and/or not approved by manifacturer.
•
The manufacturer cannot be considered responsible for damages due to
improper or unreasonable use.
INSTALLATION INSTRUCTION SEQUENCE
1
Before the installation, analyse the risks referring to the chapter "Generalities" of
this instruction manual, fill the technic table and eliminate the risks noticed.
In case of more risks, foresee the installation with security system.
2
Test the security laws of the "Security Criteria".
3
Identify the right actuator and the left actuator.
4
Control all the components.
5
Identify the fixing point on the gate and then on the pillar.
6
Verify point "D"
7
Adapt the bracket S1 o S2 following "Table1"
8
Anchor the actuator to the bracket S1 o S2.
9
Unclamp the actuator
10 Anchor the bracket S3 on the gate
11 Anchor the manina of the piston to the bracket S3.
12 Stretch the wires as in the "Operal diagram"
13 Connect the control unit and all the accessoires
14 Program the radio receptor
15 Program working times
In case of bad working, see the "Anomalies and Advises"
If you do not find any solution call the nearest Assistance centre.
LOCKED ACTUATOR
The actuators can be locked myaster 3/4/5.
Please notice that the electric lock must be installed on the wing that opens first and
must be connected with the terminal board of the control unit. Position of the electric
lock: (Fig. N).
Position 1: Lock between the wings (in this case is necessary to use the bolt RT15 on
the second wing).
Position 2: Lock in the floor (in this case the utilization of the bolt is not essential).
Remember to remove the lock or to block the lock in opening position and take away
all the bolts of lock.
RIGHT AND LEFT ACTUATORS (Fig. D)
The actuators are supplied in Right or Left version.
Right or left are established looking the gate from the side where the actuators are
installed, if the hinges are on the right the actuator is right, if they are on the left the -
actuator is left.
DETERMINATION OF FIXING MEASURES
Gate fixed in the middle of the pillar (Fig. A)
In this case the maximal opening angle of the gate is 90°.
-
The correct functioning can be obtained putting the fixing brackets at the
measures indicated in the table above picture A and B .
In the case of difficulty to install do as follows:
-
Measure the level D
(distance between the hinges' axis and the pillar's edge)
-
Look at the table 1, in the part related to the model of your operator untill the part
correspondent to level D.
-
In the below table you can find the necessary indications and establish the most
suitable use of the bracket S1 (Fig. E) or alternatively braket S2 (Fig. F).
These quotes are calculated in order to obtain an average tangential speed that does
not exceed of 12 m/minute.
Gate fixed on the edge pillar (Fig. B)
In this case the gate can open with an angle superior to 90° (max. 120°)
-
The correct functioning for a 90° deegrees opening is obtained putting the
backets to the measures indicated in the table above picture A and B.
-
In order to open the wing with a bigger angle measure A has to be superior to
measure B.
The best solution is to increase measure A of the same dimension of wich must be
diminished the measure B.
HEIGHT INSTALLATION
Determine the height where the actuator must be installed according to the gate's
shape and the fastening possibility. (Fig. G)
a) In case of sturdy structure you can position the actuator at any height with no
limits.
b) If the structure is light is necessary to put the operator as near as possible to the
centre of the gate (in height).
Position 1 Central beam of the gate
Position 2 Reinforcement of the gate The distance between the base of the actuator
collar and the floor must be more than 10 ÷15 cm.
BRACKET FIXING
Bolt or weld the bracket S1 or S2 on the gate's side pillar remember that the
measures A and B refer to the gate hinges axis and to the actuator's rotation axis.
In case of fastening by expansion bolts, use Ø13 mm metal bolts and place the bolt at
no less than 30÷35 mm from the pillar's edge, to avoid breaking it. (Fig. H)
In case of masonry pillars, use chemical or resin bolts or a cementated bracket.
-
The bracket S1 (Fig. E) has two versions: bracket S1 right end bracket S1 left;
each one should be used with its actuator.
-
Fasten the actuator to bracket S1 as indicated in "Fig. I": remember that the
threaded hole of the rotating pivot PR1 must be turned down.
BRACKETS S2 (Fig. F)
In some cases - as indicated in table 1 and for particular installation is suitable to use
bracket S2.
Each bracket has one squared plate with dimensions 130x130x6 mm, with 4 holes of
Ø12 mm and one 112x94x55 mm with 3 holes of Ø12 mm.
Instructions for installation
Screw the plate to the pillar with strong dowels
-
Weld the bracket to the plate as in Fig. F
-
Remember that the measures A and B are referred to the hinges axis of the gate
and the rotation axis.
FRONT BRACKET'S FIXING
Fix the position of bracket S3 as follows:
-
Close the gate's wing.
Release the gearmotor.
-
Let the inox ram rotate completely until reaching the mechanical stop (max.
stroke)
.
-
Retract the stainless tube approximately for 2cm.
-
Place the S3 bracket into the ram with the PR1 pin and fixing (pict. L)
(NB: lower part)
-
Lean the S3 bracket on the leaf keeping the ram perfectly horizontal (you may
better use a spirit-level) and fix the bracket with a screw or weld it.
NB: Check the manual opening of the leaf before definitively fixing the brackets
and make sure that the leaf opens completely.
MECHANICAL STOP (Fig. D).
Now is neccesary to set the mechanical stop to put the stop in opening phase. When
the gate is closed the actuator's rod may come out of maximum 335 mm for myaster
3, of maximum 435 mm for myaster 4, and of maximum 535 mm for myaster 5.
When the gate is open, the rod must be out of minimum 55 mm. (Fig. M)
EXTERNAL OPENING GATE
In case of external opening is possible to put the actuator towards the internal side.
In this case the quote A (distance between the axe of the hinges and the rotation axe
of the actuator) has to be measured towards the center of the gate (Fig. N).
It is also necessary to modify the bracket S2 to adapt it to the new fixing position.
If you do not want to reduce the lenght of the passage, you can put the actuator in the
superior part of the gate, at a height of minimum 2 mt.
The position of the front bracket can be founded with the method indicated upon, with
the wing of the gate in open position.
Due to the motor's power, all the fastenings must be sturdy.
RELEASE OF THE ACTUATOR
-
Insert the key (supplied in the kit) and rotate it of 90° many times towards the
center of the gate. (Fig. P)
-
In this way the gate may be opened or closed manually.
-
Rotate the key in the opposite direction to clasp the actuator.
The gate do not have to be in a particular position: at next start all previous value will
be restored.
ENGLISH