Horizontal Unit Heater 10KW - 240V - 1 or 3 Phase
CONTENTS
Part Qty.
1
2
Tilt adjustment knob
2
2
Rubber washer
3
1
Hex bolt M10 x 60mm L, zinc plated
4
2
Washer, 10mm, zinc plated
5
1
Spring washer
6
1
Nut
7
2
Expansion bolt
8
1
Wall hanger
9
1
Handle
10
2
Expansion Nut
Wall Mount Installation Instructions:
1. Install the unit at least 6 feet (1.8 m) away from the floor. This
minimum distance must be maintained.
2. Do not install closer than 1 foot (or 0.3 m) to any adjacent
vertical surfaces or walls.
3. Keep at least 4.5 inches (11.5 cm) from the back wall (with or
without using the wall hanging mounting bracket).
4. Determine the mounting location on the wall/ceiling and mark
the hole locations.
5. Use a 0.48 inch(12mm) drill bit and drill (2) holes 2.75 inches
deep.
6. Insert the expansion bolts (7) flush to wall or ceiling.
7. Attach the mounting bracket (8) and secure with expansion
nut (10).
10
10.94 in
8
Note: The bracket must be firmly attached to the wall before
hanging the unit
8. Hook the unit to the mounting bracket (8) and let the unit hang
from the mounting bracket (8).
1
2
Description
10.94 in
7
8
9. Insert washer (4) and hex bolt (3) through mounting bracket
(8) and heater handle (9). Tighten with washer (4), spring
washer (5) and nut (6).
Wire Connection:
10. Loosen the screw to remove the inspection window cover in
the rear of the heater.
11. Run the electrical power supply cable in conduit.
10
12. Secure the conduit to the back plate via the knock-out hole.
Knock-out Hole
13. Make the connections properly with connectors which are
suitable for the conductor size, including grounding wirings.
Pull all the conductors from the conduit. Strip 3/4 inch of insula-
tion from ground conductors. Make a right angle bend in the
green(green/yellow) pigtail and place its stripped end next to the
stripped ends of the other green(green/yellow) supply cable.
Make sure that the bare ends are tight together and square.
Using lineman's pliers, twist the bare ends tightly together in a
clockwise direction, then screw one of the wire nuts tightly on
the spliced conductors. Check to be sure that no bare copper
shows from beneath the wire nut.
4
User's Manual
10