How To Clean; Technical Data - Beper 90.380 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Induction cooker Use instructions

HOW TO CLEAN

1) Disconnect plug and wait until the unit is cooled down completely. Clean after using every time.
2) If the pots/pans are used without being cleaned, discoloration or stains may be caused.
3) Do not use benzine, thinner, scrubbing brush or polishing powder to clean the induction cooker.
4) Wipe using dish washing agent and damp cloth.
5) Use vacuum cleaner to suck up dirt from the air intake and exhaust vent.
6) Never run water over the unit (Water gets inside may cause malfunction).

TECHNICAL DATA

Power: 2000W
Power supply: 220-240V ~ 50/60Hz
For any improvement reasons, Beper reserves the right to modify or improve the product
without any notice.
Trouble code
E1
E2
E3
E4
E5
E6
E7
E8
Possible reason
Plate surface
temperature sensor
open
IGBT
Temperature sensor
open
Abnormal supply voltage;
voltage too high.
Abnormal supply voltage;
voltage too low.
late surface temperature sensor short-circui-
ted; empty
pot/pan heating leading
to too high temperature.
Fan failure;Air
intake/exhaust vent
blockage.
Coil panel is not
connected well; circuit
malfunction
No pot/pan on the plate.
Non-usable pans on the
plates.
12
Solution
Please contact the supplier
or go to a qualified service
center.
Please contact the supplier
or go to a qualified service
center.
Check power supply.
Switch on after power
supply is back to normal.
Please check power supply.
Switch on after power
supply is back to normal.
Please wait for some
minutes until the unit cools
down. Please check pot/pan.
lease contact the supplier
or go to a qualified service
center. Clean the vent after
the unit cools down, then
restart.
Please contact the supplier
or go to a qualified service
center.
Put suitable cooking
utensils on the plates.

Publicidad