Descargar Imprimir esta página

Pre-Operation Checks - Dolmar GE-1100 Manual De Instrucciones

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 69
6. DC CIRCUIT BREAKER (See Fig. 2 2 -t t )
DC circuit breakers shut off electric current when
the current exceeds its limit or a malfunction occurs
in the connected appliance.
Check for excessive current consumption or defects
in the appliance. After making sure everything is in
order, push the button to the " ON " position.
q BUTTON
w KNOB
GB
If circuit breaker continues to be
activated, discontinue use and check
GB
generator and/or appliance for
GB
malfunction with their respective service
representatives.
GB
Never interfere with the operation of the
GB
circuit breaker knob or keep pushing it in
the "ON" position.
GB
GB
7. RECOIL STARTER (See Fig. 2 2 -y y )
GB
Pull this handle to start the generator.
GB
q RECOIL STARTER HANDLE
GB
GB
8. GROUND TERMINAL (See Fig. 2 2 -u u )
GB
Terminal for grounding the generator.
GB
9. FUEL TANK CAP (See Fig. 2 2 -i i )
GB
The fuel tank cap is located behind the cover.
GB
To open the cover, lift up with the dent portion
GB
depressed backward as shown in the illustration.
Remove the fuel tank cap by turning
counterclockwise.
q FUEL TANK CAP
w FUEL FILTER SCREEN
e TANK CAP COVER
10. SIDE PANEL (L.R.) (See Fig. 2 2 -o o )
To access the following items for servicing, take the
applicable side panel out by removing the screw
with screwdriver or coin.
LH-side panel ---- Air cleaner etc.
RH-side panel ---- Oil level gauge, Ignition coil,
Spark plug etc.
6
e IN (ON) "
"
r OUT (OFF) "
"
CAUTION

4. PRE-OPERATION CHECKS

(See Fig. 3 3 )
1. CHECK ENGINE OIL (See Fig. 3 3 -q q ,w w )
Before checking or refilling oil, be sure generator is
located on stable and level surface with engine stopped.
Remove oil filler cap and check the engine oil level.
■ ■
If oil level is below the lower level line, refill
■ ■
with suitable oil (see table) to upper level line.
Do not screw in the oil filler cap when
checking oil level.
Change oil if contaminated.
■ ■
(See "How-To" Maintenance.)
Oil capacity . . . . 0.4 liters
Recommended engine oil:
Use 4-stroke automotive detergent oil of API service class
SE or higher grade (SG, SH or SJ is recommended).
SAE 10W-30 or 10W-40 is recommended for
general, all-temperature use. If single viscosity oil is
used, select the appropriate viscosity for the
average temperature in your area.
5W
10W
Single grade
Multigrade
Ambient
temperature
2. CHECK ENGINE FUEL (SeeFig. 2 2 -i i , 3 3 -e e )
WARNING
Do not refuel while smoking or near open
flame or other such potential fire hazards.
Otherwise fire accident may occur.
If fuel level is low, refill with unleaded
■ ■
automotive gasoline.
Fuel level should never over the RED marking
■ ■
at the inlet portion. (SeeFig. 3 3 -e e -q)
q RED MARKING
Be sure to use the fuel filter screen on the fuel
■ ■
filter neck.
q FUEL TANK CAP
w FUEL FILTER SCREEN
e TANK CAP COVER
Fuel tank capacity . . . . . . . . . 3.5 liters
When using the generator first time or stopping
■ ■
due the fuel running out, pull the recoil handle
several times after filling fuel up to the RED
marking at the inlet portion of the fuel tank.
20W
#20
#30
#40
10W-30
10W-40

Publicidad

Solución de problemas

loading

Este manual también es adecuado para:

Ge-1700 i