Air Supply Requirements
1. Supply tool with 70 psig (4.8 bar) of clean, dry air. Higher pressure drastically
reduces tool life.
2. Connect tool to air line using pipe, hose and fitting sizes shown in the diagram
on page 12.
Lubrication
1. Use an air line lubricator with SAE #10 oil, adjusted to two drops per minute. If
an air line lubricator cannot be used, add air motor oil to the inlet once a day.
2. The use of synthetic oils for air line lubrication is not recommended because of
possible damage to seals, o-rings, hose, and polycarbonate oiler/filter bowls.
Operation
To turn tool on, hold grip and push cap (item 15) towards stylus. To cease
operation, pull cap away from stylus.
Noise & Vibration Declaration*
Sound pressure level 65 dB(A) in accordance with Pneurop PN8NTC1.2. For
sound power, add 10 dB(A).
2
Vibration value 9.7 m/s , re. ISO 8662-2.
*These declared values were obtained by laboratory type testing in compliance with the stated standards and
are not adequate for use in risk assessments. Values measured in individual work places may be higher than
the declared values. The actual exposure values and risk of harm experienced by an individual user are
unique and depend upon the way the user works, the workpiece and the workstation design, as well as upon
the exposure time and the physical condition of the user. We, Chicago Pneumatic, cannot be held liable for
the consequences of using the declared values, instead of values reflecting the actual exposure, in an
individual risk assessment in a work place situation over which we have no control.
To reduce risk of injury, everyone using, installing,
repairing, maintaining, changing accessories on, or
working near this tool must read and understand
these instructions before performing any such task.
The goal of Chicago Pneumatic is to produce tools that help you work safely and
efficiently. The most important safety device for this or any tool is YOU. Your
care and good judgment are the best protection against injury. All possible
hazards cannot be covered here, but we have tried to highlight some of the
important ones.
For Additional Safety Information Consult:
Your employer, union and/or trade association.
US Department of Labor (OSHA); www.osha.gov; Council of the
European Communities europe.osha.eu.int
"Safety Code for Portable Air Tools" (ANSI B186.1) available from:
www.ansi.org
"Safety Requirements for Hand-Held Non-Electric Power Tools"
available from: European Committee for Standardization,
www.cenorm.be
Air Supply And Connection Hazards
Air under pressure can cause severe injury.
Always shut off air supply, drain hose of air pressure and disconnect tool
from air supply when not in use, before changing accessories or when
making repairs.
Never direct air at yourself or anyone else.
Whipping hoses can cause serious injury. Always check for damaged or
loose hoses and fittings.
Do not use quick disconnect couplings at tool. See instructions for
correct setup.
Whenever universal twist couplings are used, lock pins must be
installed.
Do not exceed maximum air pressure of 4.8 bar (70 psi) or as stated on
tool nameplate.
Projectile Hazards
Always wear impact-resistant eye and face protection when involved
with or near the operation, repair or maintenance of the tool or changing
accessories on the tool.
Be sure all others in the area are wearing impact-resistant eye and face
protection.
Operating Hazards
To prevent damage to the tool, tool must be held firmly against work
surface before tool is throttled.
Always shut off air supply, relieve hose of air pressure and disconnect
tool from air supply when changing accessories.
We, Chicago Pneumatic Tool Company, 1800 Overview Drive, Rock Hill, SC 29730
USA, declare under our sole responsibility that the product to which this declaration
relates, is in conformity with the requirements of the Council Directive of June 1998 on
the approximation of the laws of the Member States relating to machinery (98/37/EC).
Machine Name CP710 Engraving Pen
Machine Type Engraving Pen - No other use is permitted.
Serial No. Tools with No. 99032 or higher
Technical Data
Air pressure 70 psi (4.8 bar)
BPM 14,000
Air consumption 2.7 CFM
Harmonized Standards Applied EN292
National Standards Applied ISO 8662-2, Pneurop PN8NTC1.2
Name and Position of Issuer W. A. LeNeveu, President, Chicago Pneumatic Tool
Company
Signature of Issuer
Place and Date of Issue Rock Hill, SC 29730 USA, September 31, 1999
Limited Warranty: The "Products" of the Chicago Pneumatic Tool Company ("CP") are warranted to be
free from defects in material and workmanship for one year from the date of purchase. This Warranty
applies only to Products purchased new from CP or its authorized dealers. Of course, this Warranty
does not apply to products which have been abused, misused, modified, or repaired by someone other
than CP or its Authorized Service Representatives. If a CP Product proves defective in material or
workmanship within one year after purchase, return it to any CP Factory Service Center or Authorized
Service Center for CP tools, transportation prepaid, enclosing your name and address, adequate proof
of date of purchase, and a short description of the defect. CP will, at its option, repair or replace defective
Products free of charge. Repairs or replacements are warranted as described above for the remainder
of the original warranty period. CP's sole liability and your exclusive remedy under this Warranty is
limited to repair or replacement of the defective Product. (There Are No Other Warranties Expressed
Or Implied And CP Shall Not Be Liable For Incidental, Consequential, Or Special Damages, Or
Any Other Damages, Costs Or Expenses Excepting Only The Cost Or Expense Of Repair Or
Replacement As Described Above.)
Avoid direct contact with accessory and work surface during and after
work as they become heated and sharp.
Wear gloves to protect hands.
Operators and maintenance personnel must be physically able to handle
the bulk, weight, and power of the tool.
Holding the accessory with the free hand can be a source of vibration
exposure or injury.
Accessory Hazards
Chicago Pneumatic does not recommend the use of accessories with
this model.
Workplace Hazards
Slip/Trip/Fall is a major cause of serious injury or death. Be aware of
excess hose left on the walking or work surface.
High sound levels can cause permanent hearing loss. Use hearing
protection as recommended by your employer or OSHA regulation (see
29 CFR part 1910).
Maintain a balanced body position and secure footing.
Repetitive work motions, awkward positions and exposure to vibration
can be harmful to hands and arms. If numbness, tingling, pain or
whitening of the skin occurs, stop using tool and consult a physician.
Avoid inhaling dust or handling debris from the work process which can
be harmful to your health. Use dust extraction and wear respiratory
protective equipment when working with materials which produce
airborne particles.
Proceed with care in unfamiliar surroundings. Hidden hazards may exist,
such as electric or other utility lines.
This tool is not intended for use in explosive atmospheres and is not
insulated for contact with electric power sources.
Some dust created by power sanding, sawing, grinding, drilling and other
construction activities contains chemicals known to the State of
California to cause cancer and birth defects or other reproductive harm.
Some examples of these chemicals are:
- Lead from lead based paints
- Crystalline silica bricks and cement and other masonry products
- And Arsenic and chromium from chemically-treated rubber
Your risk from these exposures varies, depending on how often you do
this type of work. To reduce your exposure to these chemicals: work in a
well ventilated area, and work with approved safety equipment, such as
dust masks that are specially designed to filter out microscopic particles.
For professional use only.
CP710
Engraving Pen