Operating instructions Trumavent fan for warm air distribution and ventilation
Always observe the operating instructions prior to start-
ing! The vehicle owner is responsible for the correct operation
of the appliance.
Repairs are only to be carried out by an expert!
TEB – 12 V with automatic speedcontrol
12 V
a = Manual control (e.g. for ventilation)
Adjust desired output at the control knob.
b = Off (or automatic operation /
heating with the heater Trumatic S 3002 K)
6
Trumavent
a
man
b
c
auto
c = Automatic operation (Heating)
The output steadily adjusts to the respective heat emis-
sion of the heater. The maximum output can be limited at
the control knob, as required. The regulating between this
value and slow running is carried out autmatically.
The Trumavent fan TEB can also be operated with 230 V
by using the Truma voltage converter SPU (part no. 40000-
47700). The assembly of the SPU voltage converter should be
as close to the floor as possible. It is not possible to connect
further 12 V appliances to this voltage converter.
When power packs or power supply units are being
used, note that the output voltage is between 11 V
and 15 V and the alternating current ripple is < 1.2 Vpp. The
Truma battery charger NT 12/ 3-18 (part no. 39901-01) is
recommended for connecting multiple 12 V devices. This
charger (with a charging current of 18 A) is suitable for
charging lead-acid or lead-gel batteries. Other chargers may
be used only with a 12 V battery as a buffer.