Important Recommendations For Long-Lasting And Correct Operation Of The Boiler; Warranty Terms; Technical Parameters Of Boiler Wbs; General Features - Sunsystem BURNIT WBS Serie Manual Del Operador

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

9.4. Important recommendations for long-lasting
and correct operation of the boiler.
- C arry out periodic maintenance of boiler following
EN
the prescriptions in Section 9.3.
- T he allowed moisture content of the fuel used must
not exceed 15% ÷ 20%.
- G as emission in the combustion chamber may result
in the formation of tar and condensate (acids).
Therefore, a mixing valve must be installed and it
must be adjusted so that the minimum temperature
of the water returning in the boiler is 65° С. This
extends the life span of the boiler and its warranty.
The operating temperature of the water in the
boiler must be within the 65 ÷ 85°С range.
- I t is not recommended to operate the boiler for a
long period of time at an output lower than 50%.
- W hen using circulation pump, boiler operation must
be controlled via a separate thermostat in order
to ensure the prescribed rated temperature of the
return water.
- T he eco-friendly operation of the boiler is realized at
rated output.
- I t is recommended to install a storage/buffer tank
and pump type group with thermostatic mixing
valve to the boiler. The capacity of the storage tank
is 55 L of water per 1 kW installed boiler power.
- M aintenance and operation training for the boiler is
conducted by an authorized installer
Failure to observe the installation and
*
operating requirements described in the
manual and the service booklet voids the
warranty.
1. Temperature indicator
2. Housing
3. High efficiency thermal insulation
4. Safety heat evacuator (exchanger)
5. Three-pas flue gas flow
6. Water mantle
7. Combustion chamber
TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL
Diagram 12. Elements of WBS /see page 62/
10

10. WARRANTY TERMS

The warranty terms are described in the Service
booklet included in the supply.
11. TECHNICAL PARAMETERS OF SOLID FUEL
BOILER WBS

11.1. General features

- S imple installation and handling;
- C ombustion chamber with large heat exchanging
surface and low chamber resistance;
- L arge firebox door ensures easy loading even with
bigger wood chunks (lenght up to 50 cm);
- R ibbed chamber surface and three-pass flue gas
flow for improved heat exchange ;
- E xchangeable metallic ash grate protects the pipe
grid from the flame;
- B urner flange on lower door for fitting pellet, gas or
oil burners ;
- R emovable boiler housing with insulation;
- S afety devices:
1. T hermostatic draft regulator
2. P ressure relief valve 3 bar
3. S afety heat evacuator (safety heat exchanger)
integrated in the upper part of the water mantle, to
which may be associated with thermostatic valve.
8. Metal ash grate
9. Ash-andsoot-container
10. Burner flange (option)
11. Flue
12. Hot water outlet
13. Thermostatic draft regulator
14. Air intake flap

Publicidad

Tabla de contenido
loading

Tabla de contenido