PEGASUS D LN
EN
1. GENERAL INSTRUCTIONS
Carefully read the instructions contained in this instruction booklet.
After boiler installation, inform the user regarding its operation and give him this manual,
which is an integral and essential part of the product and must be kept with care for future
reference.
Installation and maintenance must be carried out by professionally qualified personnel, ac-
cording to current regulations and the manufacturer's instructions. Do not carry out any oper-
ation on the sealed control parts.
Incorrect installation or inadequate maintenance can result in damage or injury. The Manu-
facturer declines any liability for damage due to errors in installation and use or failure to fol-
low the instructions.
Before carrying out any cleaning or maintenance operation, disconnect the unit from the pow-
er supply using the system switch and/or the special cut-off devices.
In case of a fault and/or poor operation, deactivate the unit and do not attempt to repair it or
directly intervene. Contact professionally qualified personnel. Repair/replacement of the
products must only be carried out by professionally qualified using original spare parts. Fail-
ure to comply with the above could affect the safety of the unit.
This unit must only be used for its intended purpose. Any other use is considered improper
and therefore dangerous.
The packing materials are potentially hazardous and must not be left within the reach of chil-
dren.
The images given in this manual are a simplified representation of the product. In this repre-
sentation there may be slight and insignificant differences with respect to the product sup-
plied.
2. OPERATING INSTRUCTIONS
2.1 Introduction
Dear Customer,
Thank you for choosing a FERROLI boiler featuring advanced design, cutting-edge tech-
nology, high reliability and quality construction. Please read this manual carefully since
it provides important information on safe installation, use and maintenance.
PEGASUS D LN is a high-efficiency, low emissions heat generator for heating and do-
mestic hot water production (optional) running on natural gas or LPG (configurable at the
time of installation). The boiler shell consists of cast iron elements, assembled with dou-
ble cones and steel stays. The control system is with microprocessor and digital interface
with advanced temperature control functions.
A
The boiler is arranged for connection to an external hot water storage
tank (optional). In this manual all the functions relevant to domestic hot
water production are active only with the optional hot water tank connect-
ed as indicated in sec. 3.3

2.2 Control panel

1
2
27
26
24
3
25
23
4
22
fig. 1 - Control panel
Key
1 =
Button -
2 =
Button +
3 =
Heating system temperature setting decrease button
4 =
Heating system temperature setting increase button
5 =
Display
6 =
Summer / Winter mode selection button
7 =
Not used
8 =
Reset button
9 =
Unit On / Off button
10 =
Sliding Temperature" menu button
16 =
Outside sensor temperature (with optional outside sensor)
17 =
Appears on connecting the outside Sensor or the Remote Timer Control (op-
tionals)
18 =
Room temperature (with optional Remote Timer Control)
19 =
Burner On
20 =
Antifreeze operation
21 =
Heating system pressure
22 =
Fault
23 =
Heating delivery temperature / setting
24 =
Heating symbol
25 =
Heating mode
26 =
Set heating delivery temperature reached
27 =
Summer mode
19
5
16
bar
21
20
18
17
6
cod. 3540U012 - 02/2010 (Rev. 00)

2.3 Lighting and turning off

Boiler not electrically powered
B
The antifreeze system does not work when the power and/or gas to the unit are
turned off. To avoid damage caused by freezing during long idle periods in win-
ter, it is advisable to drain all water from the boiler, or add a suitable antifreeze
to the heating system, in compliance with that prescribed in sec. 3.3.
Boiler lighting
Open the fuel on-off valves.
Switch on the power to the unit.
For the following 120 seconds the display will show FH which identifies the heating
system air venting cycle.
During the first 5 seconds the display will also show the card software version.
When the message FH disappears, the boiler is ready to operate automatically
whenever domestic hot water is drawn or in case of a room thermostat demand.
Turning the boiler off
Press the on/off button (detail 9 - fig. 1) for 1 second.
7
9
10
When the boiler is turned off, the electronic board is still powered.
Heating operation is disabled. The antifreeze system remains activated.
To relight the boiler, press the on/off button (detail 9 fig. 1) again for 1 second.
8
The boiler will be immediately ready to operate whenever domestic hot water is drawn
or in case of a room thermostat demand.
Prolonged boiler shutdown
To shut down the boiler:
Press the ON/OFF button (9 - fig. 1)
Close the gas cock ahead of the boiler.
Disconnect the power to the unit.
B
To avoid damage caused by freezing during long idle periods in winter, it is ad-
visable to drain all water from the boiler, DHW circuit and system; or drain just
the DHW circuit and add a suitable antifreeze to the heating system.
fig. 2 - Boiler not electrically powered
fig. 3 - Boiler lighting
fig. 4 - Turning the boiler off
eco
bar
fig. 5