Description
PROXXON-Power Supply Units have been
developed to work efficiently and are built
strictly in accordance with the VDE- safety
regulations: (German Electrical Engineering
Association)
• Compact construction, Noryl casing
(particularly heat resistant)
• ports for instruments, hinged storage hooks
• Electronic overload protection (PTC)
• Thyristor regulated speed control
Technical Details
Mains supply
Off load voltage
Operational voltage
Primary rating
For use in dry environments only
Protection class II device
Please do not dispose off the
machine!
Overview
Legend (see diagram)
1
Socket for PROXXON Electrical Appliance
2
Universal connector for banana plug
(Ø 4 mm)
3
On and off switch
4
LED display
5
Hooks for electrical tools
6
ports for instruments
7
Control knob
- 6 -
230 V, 50-60 Hz
16 V
12 V (at 5 A)
85 W
Safety Considerations
For your own safety please observe the
following:
• Power Supply Units are only to be stored and
used in dry rooms.
• Power Supply Units are to be kept out of
children's reach.
• Remove the mains plug before cleaning the
Power Supply Unit.
• Keep the mains power cable away from the
working area.
• Check the power cable regularly. If it is
damaged, it must be replaced at an authorized
service center.
• Power Supply Units are to be opened only by
authorized service personnel.
• If the Power Supply Unit cuts out due to
overloading, then immediately switch off the
electrical device which is attached (danger of
uncontrolled running).
• Switch off the Power Supply Unit after use
• Do not use the Power Supply Unit for
purposes other than intended.
• Do not use the Power Supply Unit in the
vicinity of inflammable gases or liquids.
Instructions for Use
1. Ensure that the electrical appliance is
switched off before connecting to the Power
Supply Unit.
Important!
Take the necessary safety precautions to
prevent uncontrolled start up of the electrical
appliance when connecting the Power Supply
Unit (e.g., hold the appliance securely.
2. Connect to mains. Press switch 3 to turn on.
Red LED lamp 4 indicates standby.
3. Connect the electrical appliance to the Power
Supply Unit. Socket 1 has a safety
mechanism preventing damage if it were to be
poled incorrectly.