Connections with standard control panels (one or two panels)
RL1 and RL2 can be connected with a single board (ST1 and ST2) or with two independent boards.
If the ANT exterior antenna is to be connected, see the layout in section "General connections".
12
24
12
24
+5V
12
24
+5V
12
24
ST1
ST2
ST1
ST2
3

INSTALLATION AND START-UP

1 Install the required cards (RSD plug-in receiver +
1000 code plug-in memory, LINK-GSM, LINK-BT), in
line with the respective instructions.
2 Secure the box in place with suitable screws,
ensuring the location of the module is suitable for
proper reception.
3 Make the electrical connections as shown in the
previous figures.
4 Connect the control panel power supply and check
that it reaches the module (the LEDs will light up
after 5 or 6 seconds):
• DL1 flashes quickly for around 1 second if the
memory card is not inserted in its connector.
then flashes at certain intervals (only when the
cable is connected, regardless of whether the
memory card is inserted or not.
+5V
+5V
ST1
ST2
ST1
ST2
P1 P2 P3
ST1
FT1
P1 P2 P3
P4 P5 P6
P15 P14 P16
ST1
FT1
ST2
FT2
FCA1
P4 P5 P6
P15 P14 P16
P7 P8
P11 P12
P22 P23
G7 G8
Courtesy
24Vac
STOP
LOCK
ST2
FT2
FCA1
FCC1
Light
• DL2 indicates GSM signal. When it is searching for
a signal, it flashes once every second. When it has
a signal, it flashes approximately every 3 seconds.
• DL3 normally flashes approximately every 1 to 3
seconds to indicate that Bluetooth is on standby.
If there is an active, visible Bluetooth device stored
in the memory nearby, DL3 gives out a series of
flashes approximately every 5 seconds. The other
DL3 functions are described in the "LINK-BT"
manual.
5 Start up in line with the instructions for the cards
installed (RSD plug-in receiver + 1000 code plug-in
memory, LINK-GSM, LINK-BT).
It
P7 P8
P11 P12
P22 P23
G7 G8
G9 G10
Courtesy
24Vac
Lamp.
FCC1
STOP
LOCK
Light
G9 G10
P1 P2 P3
P4 P5 P6
P15 P14 P16
P7 P8
Lamp.
ST1
FT1
ST2
FT2
FCA1
FCC1
G1
G2
G3
N
L
POWER
MOTOR1 (G2-G1-COM)
P262D
P11 P12
P22 P23
G7 G8
G9 G10
Courtesy
24Vac
Lamp.
STOP
LOCK
Light
P262E
15