or pre-set via the "timer", it cannot be turned off using the
pneumatic button installed near the spa.
WATER HEATING MODE (optional)
.
The water in the spa can be warmed up via the heater or heat
exchanger (recommended temperature of 35-36°C).
(heating deactivates only when the set temperature is reached),
When continuous heating is set, if the water temperature
detected by the probe on the spa-pack is below that set, the
on until the set temperature is reached.
Timed heating can be set on a maximum of three time bands
in 24 hours.
When time bands are set, the heater remains off outside of
these, even if the water temperature is below that set.
Temperature adjustment (set point)
Press the "ON/OFF" key (the relative LED turns on), the display
shows the current water temperature in the spa; press the
"manual" key, the set "SP—" parameter is displayed (water
temperature in °C or °F) and the "+" and "-
these keys, you can modify the "set point" temperature, from a
minimum of 15 °C to a maximum of 40 °C (59÷104 °F).
To exit the setting, press the "set" key repeatedly or wait 30
seconds without pressing any key.
pump is automatically started and you must wait about two
minutes to have the actual water temperature.
Temperature maintenance
Every 30 minutes (at least), the system reads the spa water
temperature; should the water temperature drop below the
set minimum temperature value (standard 15°C), the system
temperature rises above this value.
If water heating is "deactivated", due to water heating programs
that are too short or in the presence of very cold outdoor
temperatures, the water temperature may drop to very low
levels.
ATTENTION: the "anti-freeze" protection activates in case of
heater failure.
Water temperature below 10°C:
pumps and blower turn on for 30 seconds every hour.
Water temperature below 5°C:
pumps and blower remain in motion until the temperature rises
above 7°C.
NOTE: if the "anti-freeze" function is not used in heating
mode (with heater or heat exchanger), the temperature probe
(optional) may be used to detect the ambient temperature. If
the temperature is less than or equal to 1°C, the jet pumps and
blower are activated until the temperature rises to 2°C.
SETTING OF FILTRATION AND
HEATING CYCLES (optional)
With the system in "COMMAND STANDBY" mode, keep the
"TIMER" key pressed for a few seconds, the relative LED will
turn on as well as the "+", "-" and "SET" key LEDs, while the
A0—" parameter. Repeatedly press
the "set" key to display all system main parameters in sequence.
The following parameters can be changed using the "+" and
"-" keys:
FILTRATION MODE
"On" always on
"di" deactivated
"—", higher than the start time
(default "On")
"—" higher than the start time
"—" higher than the start time

HEATING MODE

"On" always on
"di" deactivated
"—" higher than the start time
B2—: second heating cycle start time
"—" second heating cycle start time (from 00 to 23 hours)
B3—: second heating cycle end time
"—" higher than the start time
B4—: third heating cycle start time
"—" third heating cycle start time (from 00 to 23 hours)
B5—: third heating cycle end time
"—" higher than the start time
shows the current parameters (date and time).
You can exit the programming procedure at any time by
pressing any key other than "ON/OFF", "+", "-" and "set", or
wait 30 seconds without pressing any key.
the system is in "SYSTEM ACTIVE" mode and the "timer " is
"On".
OZONISER (ozone generator, optional)
The ozone generator has a pre-set operation: it turns on for 20
minutes, then remains off for 10 minutes in a cyclical manner,
so as to prevent ozone concentration in closed environments.
The ozoniser turns off when a whirlpool pump or the blower is
turned on and it remains off for a further 15 minutes after the
whirlpool pumps and/or blower are switched off.
With intense use of the spa, the ozoniser may remain off for
long periods.
WHIRLPOOL PUMPS AND BLOWER
The whirlpool pumps (Whirlpool function) and the blower
(Airpool function) are activated using the pneumatic buttons.
If the pneumatic buttons are disabled, the operation can be
performed using the spa-pack control keyboard.
Press the "set" key, the display shows "P1.0" (whirlpool pump 1)
and the "+" and "-" key, with which to set "P1.1", light up. Press
the "set" key to save the entered parameter, thus switching to
the next "P2.0" parameter (whirlpool pump 2), which can be
P2.1". Pressing "set" again saves the value and
switches to the third "BL.0" parameter (blower), which is also
BL.1". Press "set" again to save and exit the
program.
Devices where the "status" changes from 0 to 1 only start with
31
EN
(default =07)
(default=18)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Myspa of 250/225

Tabla de contenido