Servicing; Cleaning; Service Intervals - Parker Pneudri Maxi MX102 Guia Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 111
MX 102 - MX110 User Guide
5.

Servicing

The recommended Service procedures identified in table 5.2 and all other repair and calibration work should be undertaken by a
domnick hunter trained, qualified and approved engineer.
5.1

Cleaning

Clean the equipment with a damp cloth only and avoid excessive moisture around any electrical sockets. If required you may
use a mild detergent, however do not use abrasives or solvents as they may damage the warning labels on the equipment.
5.2

Service Intervals

Description of Service Requirements
Component
Dryer
Check POWER ON indicator is illuminated.
Check STATUS / FAULT indicators located on the
Dryer
controller.
Dryer
Check for air leaks.
Check the pressure gauges during purging for excessive
Dryer
back pressure.
Check the condition of electrical supply cables and
Dryer
conduits.
Dryer
Check for cyclic operation.
Replace the active exhaust silencers
Dryer
Recommended Service A
Replace the inlet, outlet and control air filters, and
service drains.
Filtration
Recommended Service B
Replace / Calibrate dewpoint transmitter (DDS Units
only).
Dryer
Recommended Service C
Replace the valve seats and seals.
Dryer
Recommended Service D
Replace the Desiccant.
Dryer
Recommended Service E
Operation
Table 5.2
12
Typical Recommended Service Interval
Check
Replace