8
MAINTENANCE
First days of maintenance
During the first 10-15 days your pool system will require more attention and the following care:
Make sure the pH remains on the ideal level (7,2 - 7,5). If the pH is unusually unstable and uses a lot of acid check the alkalinity
1
(recommended levels between 80 y 120 ppm).
The pool must be vacuumed and the skimmers cleaned whenever necessary to ensure perfect water conditions.
2
REMEMBER that the system requires a certain amount of time to adapt to your swimming pool and will require additional chemicals
during the first 3-5 days.
Cleaning the titanium cell
If necessary, carry out a monthly visual inspection. To clean the cell:
Remove the cell from its support (after turning off the filtration system and closing off the necessary valves).
1
Place the cell for no more than 10 minutes in 15% hydrochloric acid (1,5 l of acid for each 8,5 l of water).
2
Once the incrustations have softened remove with a hose to complete cleaning the cell.
3
DO NOT USE METALIC OR SHARP OBJECTS TO REMOVE INCRUSTATIONS. Scratching the edges or surface of the cell will make it
vulnerable to chemicals, deteriorate the cell and cancel the guarantee.
Fortnightly checks
FREE CHLORINE:
1,0 - 2,0 ppm
pH:
7,2 - 7,5
General maintenance
The pool must be vacuumed as usual and the skimmers emptied whenever necessary.
1
FILTER BACKWASHING: The system requires only occasional filter backwashing; once every 20 days should be sufficient (providing
2
the filter pressure does not exceed 1 bar, in which case a backwash may be necessary).
VERY IMPORTANT:
Make sure the cell is off while cleaning the filter. To do so, disconnect the flow switch of the cell (thin cable)
while cleaning the filter.
ADDING NEW WATER: Always through the skimmers so that the new water passes through Neosal system before entering the pool.
3
Remember to add the necessary salt (5-6 gr) per added liter of water.
In winter changing the pool water is not recommendable. We recommend that the system runs 2-3 times per week (2-3 hours per day).
4
6
Monthly checks
TOTAL ALKALINITY (TAC) pH:
80 - 125 ppm
SALT CONCENTRATION:
4.000 - 6.000 ppm
CYANURIC ACID:
30 - 50 ppm
TITANIUM CELL:
Visual inspection to
detect incrustations.