Troubleshooting
Symptom
Cause of Failure
Device not responding
The device is not wired to
and LED not displaying
the mains power correctly
LED displaying, but
The connected load has
cannot control On/Off
its own on/off switch
status of connected load
Can press button to
Binding was not
control, but cannot control
successful
by RF
Cannot dim to the
Max dim level in gateway
brightest level when in
is set to 2-wire instead of
3-wire configuration
3-wire settings.
Wattage of LED lamp is
lower than the minimum
required load for this unit.
Dimmable LED flashes
LED lamp is not
compatible
Adding the capacitor
3-wire
WARNING: To prevent any electrical short circuit, make sure the exposed wires of the
capacitor terminals are fully tucked inside the connector of the module.
Recommendation
Check if wiring is correct, or voltage is
too high or too low
Turn the switch of the connected load to
On.
Binding again using the manual binding
steps in the next section
Through the gateway's interface set the
Max level to 3-wire settings.
Use LED lamp with higher wattage than
minimum required load, see the
Specification section
Try adding the capacitor that is shipped
with this module. Connect the capacitor
between the L and LS terminal as
shown below.
2-wire
3

Reset to Factory Settings

To reset the unit back to factory default state:
1.
Make sure the LED on the unit is turned off. If it is on, press the Link Key once to turn it
off.
2.
Press and hold the Link button on the in-wall module for 3 seconds until its LED turn on
then release. The LED will start to flash.
3.
Press and hold the Link button again for more than 6 seconds until the LED turns off,
then release. The LED will flash every 2 seconds indicating the unit is now reset back to
factory default settings.
Initial Power Up and Auto Binding
Once reset back to factory settings and first powered up again, the unit will automatically
enter binding mode in an attempt to pair with any U-net compatible Gateway. This is called
Auto-binding.
If a gateway is not present and the 30 seconds period expires, the LED indicator on the unit
will flash slowly every 2 seconds, implying that the unit has never paired with any device.
Auto-binding can be restarted again by disconnecting and reconnecting power to the unit.
Note: During the Auto-binding period of 30 seconds, the Control button is dedicated for
binding use only. Pressing the Control button will not turn on/off the connected light bulb.
Specifications
Model name
AD150-1 (EU)
Frequency Range
868.30MHz
Power Input
220-240V,50Hz
Working Temperature
0°C - 40°C
Switch Type supported
Binary switch / Tact (push button) switch
Incandescent lamp, LED, CCFL
Lamp type
(Fluorescent tubes supported)
3-wire: 6W~300W
Incandescent
2-wire: 8.3W~300W
3-wire: 6W~120W
Dimmable LED
2-wire: 8.3W~120W
Supported
Non-Dimmable
Load
LED
3-wire: 6W~120W
(On/Off function
2-Wire: see note below*.
only, Dimming not
supported)
AD150-2 (US)
923.00MHz
120V/60Hz
3-wire: 6W~150W
2-wire: 8.3W~150W
3-wire: 6W~120W
2-wire: 8.3W~120W
3-wire: 6W~120W
2-Wire: see note below*