INSTALLATION MANUAL
the total load. For the total load calculation check plate data
printed on the product label.
- If more than one device must be connected to the power supply
ensure that the total sum of the power absorbed by the devices
(check the plate data shown on the product label) does not exceed
the maximum power permitted by the Converter.
HOW THE TRACK + TRACK controller WORKS
Switching on and off takes place by simply approaching your hand
to the sensitive IR switch (E), keeping a steady hand in front of it
you can adjust the intensity of light. A short flash of the light
indicates the achievement of maximum brightness.
The luminosity level obtained will be saved until the next
adjustment.
The output cable of the TRACK CONTROLLER can handle a load of
max. 72W @ 24Vdc.
The luminaire is equipped with a safety program that switches off
TRACK after 18 hours of continuous operation.
HOW THE TRACK + TRACK controller IR WORKS
TRACK IR is equipped with a selector (H) for enabling the IR
sensors (RH or LH) depending on the type of assembly, if the cable
has a RH or LH output.
To install TRACK IR in units with doors in reflective white, gloss or
mirror finishes that reflect on surfaces with non-matt finish,
consult the values given in table 1 (T1).
It is therefore advisable to perform an operating test before the
final installation of the product.
CAUTION: When installing on wardrobes with overlapping sliding
doors, the correct operation of the sensor may be compromised
(check before installation).
EN
This device must be connected directly to the power supply and
must never be connected downstream of other electronic
switches or be close to electromagnetic sources or heat sources,
and must not be exposed to direct light.
ATTENTION
- If external flexible cable or cord of this luminaire is damaged, it
shall be replaced by a special cord or cord exclusively avaible from
the manufacturer or his service agent.
- The LED module of these luminaires cannot be replaced.
- In the event of failure, the entire luminaire must be replaced.
- Never run any cable through sharp corners and edges.
- If the cable needs to be secured use only insulated clips or plastic
cable ties.
- Make sure that the cable is not crushed between the wall and
the cabinet.
- Never use extension cables that are not compatible with the
original connection system.
WARRANTY
- The warranty on the device is valid only if powered by a power
supply provided by DOMUS Line. The warranty's general terms
and conditions for this device are available at
www.domusline.com