AVENTICS | 8940400122, R412010842 | R412022205–BAL–001–AB | English
Intended use
The diaphragm pressure switch is a pneumatic device that
is used to monitor pressure values. It is intended for
application in a machine or system. It may be operated
only in the installed state.
O Observe the performance limits listed in the technical
data.
The product is intended for professional use only.
Use with oxygen:
The maximum working pressure when using with oxygen
must not exceed 10 bar.
O Always observe the relevant accident prevention
regulations.
Improper use
Improper use includes installing the diaphragm pressure
switch in hydraulic systems or applying aggressive or
flammable gases, or liquids, to it.
AVENTICS GmbH is not liable for any damages resulting
from improper use. The user alone bears the risks of
improper use of the product.
Personnel qualifications
The work described in this documentation requires basic
mechanical and pneumatic knowledge, as well as
knowledge of the appropriate technical terms. In order to
ensure safe use, these activities may therefore only be
carried out by qualified technical personnel or an
instructed person under the direction and supervision of
qualified personnel.
Qualified personnel are those who can recognize possible
hazards and institute the appropriate safety measures,
due to their professional training, knowledge, and
experience, as well as their understanding of the relevant
regulations pertaining to the work to be done. Qualified
personnel must observe the rules relevant to the subject
area.
General safety instructions
W
Observe the regulations for accident prevention and
environmental protection.
W
Observe the safety instructions and regulations of the
country in which the product is used or operated.
W
Only use AVENTICS products that are in perfect
working order. Exchange faulty diaphragm switches
immediately.
W
Follow all the instructions on the product.
W
Only use accessories and spare parts approved by the
manufacturer.
W
Comply with the technical data and ambient conditions.
W
Never modify the product on your own authority.
Safety instructions related to the product
and technology
Improperly installed compressed air lines!
Danger of injury!
O Lay the compressed air lines so that no one can trip
over them.
General instructions on equipment and
product damage
Mechanical loads!
Damage to the device!
O Make sure that you never expose the device to
mechanical loads or mount it with mechanical
stress.
O Avoid mechanical stress when connecting the
pneumatic tubing and the electrical connection.
3
Delivery Contents
The delivery contents include:
W
1 diaphragm pressure switch
(R412010842 or 8940400122)
W
1 set of operating instructions, R412010842
4
Device Description
The diaphragm pressure switch monitors a set pressure
value. When the pressure changes, the integrated
diaphragm moves. The deflection of the diaphragm
depends on the pressure force and the adjustable pre-
loaded spring. With the adjustment screw you can adjust
the deflection of the diaphragm so that an electrical
contact is closed as soon as the set pressure is exceeded.
Device overview
5
2
3
SW 24
4
1
CAUTION
NOTICE
1 Pneumatic connection
– R412010842:
G1/8, max. M
7 Nm
D
– 8940400122:
R1/8, tapered
2 Electrical connection
3 Adjustment screw for the
switching point
4 Sealing ring (not in scope of
delivery)
5 Connection cable with socket
(not in scope of delivery)
5