3.
Warranty
Liability is accepted according to the General Terms and Conditions of Business and
Supply.
Use original replacement parts only!
4.
Important Notes
• Installation, commissioning and maintenance are to be performed only by a
qualified technician according to the instructions provided and in accordance with
legal requirements and acknowledged rules of technology.
• All technical connection regulations specified by the local water and electricity
supply utility companies must be complied with.
• All rights reserved to make technical alterations.
5.
Application
Wireless module (GSM) with antenna connection for mobile remote maintenance of
the AQUA 3000 open fittings network and communication by SMS. For permanent
connection to ECC2 function controller.
Necessary accessories:
– Antenna
– SIM card without PIN interrogation
– Telemetry service contract (http://www.franke.com/content/washroomsystems/
de/de/home/service_support/download.html)
6.
Dimensions
7.
Assembly Instructions
☞
Attach the wireless module (1) to a rail.
7.1
Snap-lock the lower edge (3) into the rail.
7.2
Press up the wireless module.
7.3
Snap-lock the upper edge (2) into the rail.
7.4
Connect the antenna cable (4).
7.5
Connect the cable from the ECC2 function controller to the wireless module (5).
8.
Function
• When power is supplied to the ECC2 function controller (1), the "Power" LED
lights up.
• When the wireless module (2) has logged into a wireless network, the "GSM" LED
is on.