Operating and maintenance
SAFETY DRIVE
User locked.
INLET FITTING
Ref.Fagor: 02201009
PARTICLE FILTERS
Change filters every two years.
Change the filters if the initial
pressure has fallen by 40%.
Pay attention to
the seals.
The vessels and filters
can be demounted by
unscrewing them.
1. 5 filter / Ref.Fagor: 02201006
2. 0.3 filter / Ref.Fagor: 02201007
Additionally, the polycarbonate vessels
can be replaced with nylon vessels
(these having a greater resistance to
chemical agents).
Ref. Fagor: 02201013
MOUNTING THE
EQUIPMENT
It is fixed using two 5 metric
screws.
1
2
EXHAUST VALVES
The vessels are emptied when they are filled or
when pressure reaches the equipment.
It is possible to force the venting by screwing the
valves. The valves have threads to connect
drain hoses to them.
AI-1000 - v1911 - página / page 4/8
PRESSURE GAUGE
0.1 MPa = 1 Bar
By removing the cover and using two
pins adjust the visual range of the
nominal value (example 0.02 MPa).
OUTPUT FITTING
Ref.Fagor: 02201010
DRIVE
Adjust the output
pressure of the unit.
OIL FILTER
Change the filter every two years.
Change the filter if the initial
pressure has fallen by 40%.
Change the filter if red dots
can be seen through the sight
glass.
Pay attention to the
direction of the filter
when changing it.
Replacement filter.
Ref.Fagor: 02201008