Additional
module with
adapter cable
Possible combinations for the solar operation of e.GO! :
1 or 2 solar modules connected with the base unit via hinge (standard configuration).
Optional additional module connected via cable adapter to the DC input socket.
Both options above combined, 1 or 2 solar modules via hinge and the optional module via cable adapter.

7. Technical data

Nominal power of solar modules: 1.1 W (FUN), 2.2 W (MASTER), 2.4 W (PROFESSIONAL)
Output power for operation of an external device: 1.3 / 2.5 / 4.0 W (at 5 V to 10 V output voltage and 25°C)
Output voltage range: 4 ... 14 V (depending on adapter cable)
Input voltage / current DC input socket: 4.5 ... 5.5 V / max. 1.8 A
Charging current internal batteries: max. 1 A per battery or battery string
Closed-circuit current in stand-by mode: 0.8 mA (with 2 AA batteries)
Voltage range mains adapter: 90 ... 270 V AC, EN standard mains plug
Ambient temperature range: 0 ... +45°C (storage), -20 ... +50°C (discharge and storage), +10 ... +30°C (recommended
operating range)
Max. rel. humidity: 95%
Safety class: IP52
Quality standard / conformity / legal rules: CE, RoHS, EMV according to EN 55014
Case materials: PC-ABS, PMMA, Santoprene
Dimensions: 160 x 90 x 36 mm
Weight: approx. 210 / 300 / 420 gr. without batteries (e.GO! FUN / MASTER / PROFESSIONAL incl. rubber housing
protection)
8. How to solve problems
Table 3: Problems and possible remedy
Symptom
Batteries not being charged after several
hours in spite of connected mains adapter
Batteries not being charges after several
hours in spite of fully insulated solar module
No LED shines despite attached mains
adapter or fully insulated solar module
and/or attached external device and/or
charged batteries inserted
Connected consumer device cannot be
charged or operated
Note: At abnormal functioning of e.GO! first remove all power sources (batteries, mains adapter) and fold solar modules, then wait at least 10 seconds and finally
reconnect e.GO!. If there is no normal function then, go on as described above.
Possible causes
Soiled batteries or faulty electronics
Soiled battery or hinge contacts
Solar module or faulty electronics
Max. temperature range exceeded
Soiled battery contacts
Faulty electronics
No charged batteries inserted and
insufficient solar insulation
Faulty contact at DC input socket or output
plug adapter
Faulty output or input cable
Faulty electronics
5
Remedy
Cleaning battery contacts with
contact spray or alike
Exchanging batteries or getting in touch with
SOLARC's customer service for device repair
Cleaning battery contacts with contact
spray or alike
Cleaning hinge pins with contact spray or alike
Exchanging batteries or getting in touch with
SOLARC's customer service for device repair
The operating temperature range must be
reached (cooling down or heating up the device)
Cleaning battery contacts with
contact spray or alike. Getting in touch with
SOLARC's customer service for device repair.
Inserting charged batteries or orienting the
modules towards the sun (if available). Try
connecting the mains adapter. If then working,
faulty solar module or insufficient sun. If
possible, try other plug adapter or output cable; if
working, then faulty cable or adapter. If any of
the components faulty, please get in touch with
SOLARC's customer service for device repair.

Publicidad