ItaldibiPack DIBIPACK 6084 Instalación Uso Y Mantenimiento página 46

Tabla de contenido

Publicidad

Via Europa, 35 - 20010 Pogliano Milanese (MI) - Tel. 02/9396161 r.a. - .ax 02/93549494
Via del Mare 32/A (interno D) - 00040 Pomezia (Roma) - Tel. 06/9100417 - .ax 06/9100430
PROBLEM
THE HOOD DOES NOT OPEN
THE HOOD DOES NOT OPEN COM-
PLETELY
THE WIRE GIVES OFF SMOKE DURING
SEALING
THE MACHINE DOES NOT REACH THE SET
TEMPERATURE
THE MACHINE SEALS BUT DOES NOT
SHRINK-WRAP THE FILM
SHRINK-WRAPPING IS PERFORMED BUT
IT IS IRREGULAR AND INCOMPLETE
THE PACKAGE IS SWOLLEN AFTER
SHRINK-WRAPPING
THE SEALING OPENS DURING SHRINK-
WRAPPING
IRREGULAR SEALING
SEALING IS NOT PERFORMED
Note: If the machine still does not function perfectly after having carried out the aforementioned checks, contact the Service Centre with an
exact description of the fault encountered.
GB
TROUBLE SHOOTING
PROBABLE CAUSE
Broken torsion bar.
Torsion bar not sufficiently loaded.
Sealing time too long for the type of film used.
Plastic residue on wire.
Heating element broken
Probe broken (interrupted)
Shrink-wrapping not selected.
Heating element broken.
Probe broken.
The fan or fans do not turn
The signal lights are on but the fan does not
rotate.
The heater door does not open
Unsuitable or low-quality film.
The product to be packaged is too large and
takes up the entire resting surface.
The film used is not micro-perforated.
Sealing wire dirty or damaged.
Rubber and/or Teflon worn out.
Sealing time incorrectly adjusted.
Insufficient pressure on the handle of the
hood.
The film used has good shrink-wrapping
characteristics but bad sealing characteristics.
Sealing time set too low.
The sealing wire is broken or not connected
to the clamps.
39
SOLUTION
Call the Service Centre.
Tighten the special screw.
Reduce the value of the sealing time, adapting
it to the type of film used.
Clean.
Replace
Replace
Check that the position of the lever-switch
(1); downwards
Replace.
Replace.
One of the motors could be broken. Consult
the Service Centre
Malfunctioning of the microswitch or broken
fan motor.
Call the Service Centre.
Call the Service Centre
The film used must be the shrink-wrapping
type.
The dimensions of the product must always
be less than those of the resting surface.
Make the film pass through the micro-piercing
device of the machine
Clean the sealing wire; check that it is resting
correctly in its position and change if
necessary.
Adjust.
Slightly increase the pressure on the handle
of the hood during sealing.
Replace the film.
Adjust according to the type of film.
Check the clamps of the sealing wire and
make sure that the latter is not broken; replace
if interrupted.
DIBIPACK 6084

Publicidad

Tabla de contenido
loading

Tabla de contenido