performed to ensure that compliant in-
stallation has been performed.
- The control unit is not equipped with
230 Vac electric line sectioning device.
The installer is responsible for install-
ing a sectioning device in the system.
The sectioning device must be protected
against accidental closing in compliance
with 5.2.9 section of EN 12453.
- For the power supply cables, use flex-
ible cables in an insulating sheath in
harmonised polychloroprene (H05RN-F)
with a minimum conductor section of
1mm
.
2
- The various electrical components ex-
ternal to the control unit must be cabled
in accordance with standard EN 60204-1
as amended, and as set forth in point
5.2.7 of EN 12453. The power supply ca-
bles can have a maximum diameter of
14 mm; the power supply and connect-
ing cables must be set up through the
assembly of cable glands, supplied as
"optional". Pay careful attention when
9