MOUNTING; SEE FIGURE 3
1. Undo the fastening nut (H) from the adapter (D).
2. Place the device at the desired place.
3. Tighten the fastening nut (H) back on the adapter (D), on the inside of the filter. Make sure that the O-ring (I) sits
properly between the adapter (D) and the filter.
4. Check the whole assembly for possible leaks.
5. Ensure that enough water flows through the device and plug the device into the appropriate socket. On the
electronics box (A), all the lights will flash and the green one will stay on.
6. The device can be turned off by simply pulling the plug out of the socket. The electronics box records how many
hours the lamp has been on.
MAINTENANCE AND DISASSEMBLY
The device needs maintenance at least once per half year. During maintenance, the device must be disconnected
from the mains. Chalk deposits and possibly algae must be removed from the quartz sleeve (E) and the
housing (D). The UV-C lamp (B) only has to be changed after 12,000 hours of use. The actual lifetime is dependent
on the number of times it is turned on and off. The electronics will indicate when the lamp has been on for
12,000 hours.
1. Unplug the device from the mains and close the pipes.
2. Ensure that the water is drained out of the filter.
3. Loosen the lock nut (C) and disconnect the UV-C lamp (B) from the lamp holder (F). If necessary, you can also
replace the lamp (see point 10 to reset).
4. Carefully raise the quartz sleeve (E).
5. The quartz sleeve (E) can be cleaned with an appropriate cleaner. After cleaning, rinse the quartz sleeve (E)
thoroughly. Use a soft cloth to avoid scratches!
6. After cleaning, place the quartz sleeve (E) back in the adapter (D). Ensure that the O-ring (G) is seated properly.
7. Put the UV-C lamp (B) into the lamp holder (F) and slide both into the quartz sleeve (E).
8. Tighten the lock nut (C) on the adapter (D) hand-tight (see 9 under Installation of the device).
9. After changing the UV-C lamp (B), the device needs to be reset. To do this, press and hold button (J) on the
electronics box (A) for 5 seconds. After this the green light will come on.
If in any doubt seek the advice of a certified electrician!
(The underlined phrases in the manual are meant only for the Module incl. timer function).
GB