IDENTIFICATION
The storage cylinders themselves and the complete system
are identified by:
Data plate
The
T
TSOL LIGHT S ANK
tem is identified by system data plates marked with the code,
description and serial number of the product.
RIELLO S.p.A.
Via Ing.Pilade Riello 7
37045 Legnago (VR) - ITALY
SISTEMA - SYSTEME - SYSTEM - SYSTEEM
Mod.
Cod.
N°
RIELLO S.p.A.
Via Ing.Pilade Riello 7
37045 Legnago (VR) - ITALY
Mod.
Cod.
N°
RIELLO S.p.A.
Via Ing.Pilade Riello 7
37045 Legnago (VR) - ITALY
SOLARBOILER
SOLAR STORAGE CYLINDER
Modell
Herstell. Nr.
Model
Serial number
Artikel Nr.
Baujahr
Code
Year
Leistungsaufnahme obere Rohrschlange
[Primärkreislauftemperatur T=80°C]
kW
Power absorbed by top coil (T° primary 80°C)
Warmwasserbereitung - obere Rohrwendel [∆T 35°C]
l/1'
Domestic hot water production – top coil [∆T 35°C]
Wärmetauschfläche obere Rohrwendel
m
2
Top coil heat exchange surface area
Wärmetauschfläche untere Rohrwendel
m
2
Bottom coil heat exchange surface area
Maximaler Boilerbetriebsdruck
bar
Maximum working pressure of storage cylinder
Boilerfassungvermögen
l
Storage cylinder capacity
Elektrischer Leistung
W
MIN / MAX
Electrical consumption
Anschlussspannung
V-Hz
Power supply
Verluste nach EN 12897
W
Heat loss according to EN 12897
ERDUNG OBLIGATORISCH - OBLIGATORY GROUND CONNECTION
These plates also list the storage cylinder's technical specifi-
cations and performance.
They are supplied in the documentation envelope delivered
with the system and must be applied to the solar storage cylin-
der on completion of installation.
b
For the identification of the collectors, see the specific
handbook.
b
If these plates or any other means of clearly identifying
the product are defaced, removed or lost, proper instal-
lation and servicing may be rendered difficult.
ENGLISH
solar water heating sys-
T067784ED
TECHNICAL SPECIFICATIONS
DESCRIPTION
Total exposed surface (A
Energy
consumption
pump (solpump)
Consumption in stand-by
(solstandby)
Annual non-solar Ca-
loric
contribution*
(Q
)
nonsol
Annual auxiliary electricity
consumption (Q
)
aux
Value calculated in terms of primary electrical energy and/
(*)
or calorific content of fuel under average climatic condi-
tions, in load profiles M, L, XL and XXL, with permanent
backup and storage cylinder inside building.
b
For technical data about the individual components, see
the specific handbooks.
6
TSOL LIGHT S ANK
200
300
)
2,16
4,32
sol
of
60
60
3
3
M
904
769
L
1862
1310
XL
3316
2464
XXL
4446
3459
146
146
GENERAL INFORMATION
m
2
W
W
kWh/a
kWh/a
kWh/a
kWh/a
kWh/a