R&S
TS-PMB
8 Self-Test
The R&S TS-PMB has a built-in self-test capability. The following tests are implemen-
ted:
●
LED-Test
●
Power-on test
●
TSVP Self-Test
8.1 LED Test
After power-on, all three LED's light up for around three seconds to indicate that the
5 V supply is present and all LED's are working. The following statements can be made
about the different LED states:
Table 8-1: Statements about the LED Test
LED
One LED does not
light up
No LED's light up
8.2 Power-On Test
The power-on test runs at the same time as the LED test. The red LED lights up if a
fault is found on the module. This is just a test of the command interface and the firm-
ware of the R&S TS-PMB.
8.3 TSVP Self-Test
The TSVP self-test runs an in-depth test on the module and generates a detailed log.
The TS-PSAM modules is used as a measuring unit of R&S modules in the TSVP. The
correct operation of the modules is ensured by measurements on the analog bus.
You can find information about starting the self-test and the order of required work
steps as well as a detailed description of parameters and sequences that are tested in
the R&S CompactTSVP / R&S Power TSVP Service Manual.
User Manual 1153.5233.12 ─ 05
Description
Hardware problem on the module
LED faulty
No +5 V supply
Self-Test
TSVP Self-Test